Precautions for Correct Use
The input variables are not allowed to omit. An error will occur during the compiling of the software if
any input variable is omitted. But the output variable is allowed to omit.
The data type of output variables must be BOOL. Otherwise, an error will occur during the compiling
of the software.
Programming Example
The data types of GT_In1, GT_In2 and GT_In3 are INT, UINT and DINT respectively and the
data type of Out1 is BOOL.
Out1 changes to TRUE when the values of GT_In1, GT_In2 and GT_In3 are 100, 50 and 10
respectively and GT_EN changes to TRUE as shown in Variable 1.
Out1 changes to FALSE when the values of GT_In1, GT_In2 and GT_In3 are 20, 10 and 100
respectively and GT_EN changes to TRUE as shown in Variable 2.
Variable 1
Variable name
GT_EN
GT _In1
GT _In2
GT _In3
Out1
Variable 2
Variable name
GT_EN
GT _In1
GT _In2
GT _In3
Out1
The Program
The data types of GT_In1 and GT_In2 are both TIME and the data type of Out1 is BOOL.
Out1 changes to TRUE when the values of GT_In1 and GT_In2 are T#100ms and T#50ms
respectively and GT_EN changes to TRUE.
The variable table and program
Variable name
GT_EN
GT _In1
GT _In2
Out1
Data type
BOOL
INT
UINT
DINT
BOOL
Data type
BOOL
INT
UINT
DINT
BOOL
1
GT
G T_EN
E N
ENO
GT_In1
I n1
O ut
Out 1
GT_In2
I n2
GT_In3
I n3
Data type
BOOL
TIME
TIME
BOOL
1
GT
G T_EN
E N
ENO
GT_In1
I n1
O ut
Out 1
GT_In2
I n2
Chapter 8 Logic Instructions
Current value
TRUE
100
50
10
TRUE
Current value
TRUE
20
10
100
FALSE
Current value
TRUE
T#100ms
T#50ms
TRUE