Service and maintenance
9.1 Diagnostics
9.1.2

Diagnostics via display elements

The operating statuses of the reader are displayed by the "RUN/STOP", "ERROR",
"MAINTENANCE" and "PRESENCE" LEDs. The LEDs can adopt the colors green, red or
yellow and the statuses off
Table 9- 1
Display of operating statuses
R/S
ER
--
--
--
--
--
--
--
--
Only exists with RF680R/RF685R.
1)
Only exists with RF650R.
2)
228
MAINT
PRE
Meaning
1)
2)
The device is turned off.
The device is starting up.
--
--
The device is ready for operation. The connection to the XML application
or S7 CPU is not established or the connection is established but an
error has occurred.
--
--
The device is ready for operation. The connection to the XML application
or S7 CPU is established.
--
--
The device is working.
Flash test for reader identification.
--
--
There is an error. You will find more information on error messages in
the section "RF650R/RF680R/RF685R error messages (Page 234)".
--
--
The network load too high. The functioning of the device is being dis-
turbed due to receiving too many network packets.
--
The antenna is switched on. There is no transponder in the antenna
field.
--
There is at least one transponder in the antenna field.
--
One or more transponders have been detected as valid.
, on
, flashing
:
STEP 7: The "writeconfig" command was received.
XML application: The "hostGreeting" command was received.
Configuration Manual, 10/2015, C79000-G8976-C386-03
SIMATIC RF650R/RF680R/RF685R