XML interface
8.3 XML commands
The command remains active during the entire duration. In the implementation of the client
application, make sure that timeout monitoring is used. The configuration parameters of the
data source (read cycles per trigger, read timeout, ...) are not used. You will find more
information on parameters in the section "The "Settings - Read points" menu item
(Page 46)".
Note
Filter mechanisms influence the results
Defined filter mechanisms influence the results (refer to the section "The "Settings - Filters"
menu item (Page 60)"). Then in the reply frame, only the transponders that were not filtered
out appear.
Note
Delay of the reply frames
A reply frame of the reader can be delayed additionally by the set duration of the command.
Command
<frame>
<cmd>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
178
<id> value_id </id>
<getObservedTagIDs>
<sourceName> value_sourceName </sourceName>
<duration> value_duration </duration>
<unit> value_unit </unit>
</getObservedTagIDs>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getObservedTagIDs>
<returnValue>
<tag>
<tagID> value_tagID </tagID>
<tagPC> value_tagPC </tagPC>
<utcTime> value_utcTime </utcTime>
<antennaName> value_antennaName </antennaName>
<rSSI> value_rSSI </rSSI>
// opt
// opt
// opt
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
// opt
// opt
// opt