Configuring with the WBM
6.3 The menu items of the WBM
①
②
③
Basic settings
In this area, you can select the read point and antenna whose optimum activation power you
want to measure.
With the "Start/Stop measurement" ( / ) and "Delete display" ( ) buttons, you can control
the power measurement.
By clicking the
the selected antenna and the measured values obtained are displayed. Any existing
measured values from a previous recording are deleted. By clicking the
recording is stopped. Clicking the
Measuring range settings
Using the four input boxes in this area, you can influence the measurement.
● Power from ... to ...
Specifies the range of values (dBm value) within which the measurement is made. The
measurement starts at the "from" value and ends automatically as soon as the "to" value
is reached.
● Increment
Specifies the dB value by which the radiated power is increased step-by-step during the
measurement.
● Time interval
Specifies the time after which the radiated power is increased by the dB value increment
during the measurement.
74
Select the required antenna, enter the required values and start the measurement.
Select a transponder from the list.
Transfer the activation power to the "Radiated power" input box of the "Settings - Read
points" menu item.
button, a new recording is started. Reads are then performed cyclically on
button deletes the currently displayed measured values.
Configuration Manual, 10/2015, C79000-G8976-C386-03
button, the
SIMATIC RF650R/RF680R/RF685R