Settime - Siemens SIMATIC RF650R Configuration Manual

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

XML interface
8.3 XML commands
8.3.2.9

setTime

This command sets the internal reader clock.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 211)".
Parameter
Parameter
value_id
value_utcTime
160
<id> value_id </id>
<setTime>
<utcTime> value_utcTime </utcTime>
</setTime>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setTime/>
Type
Decimal value
0...9
Time
Values
Description
0...4294967295
Unique command identifier
--
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
Configuration Manual, 10/2015, C79000-G8976-C386-03
SIMATIC RF650R/RF680R/RF685R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf680rSimatic rf685r

Table of Contents