The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 211)".
Parameter
Parameter
value_id
value_ioName
value_ioEvent
value_utcTime
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
<id> value_id </id>
<resultCode> 0 </resultCode>
<ioer/>
Type
Decimal value
0...9
Fixed values
Fixed values
Time
Values
Description
0...4294967295
Unique command identifier
Inport00
Name of IO port
Inport01
Inport02
Inport03
Outport00
Outport01
Outport02
Outport03
High
Indicates the new status of the in-
Low
put/output.
--
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.