Parameter
value_power
value_polarization
value_
commandRetry
value_airRetry
Value_
filterDataAvailable
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Type
Values
Decimal value
0, 5.00...33.00
0...9
Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Decimal value
0..65535
0...9
Decimal value
0..65535
0...9
Fixed values
True
False
XML interface
8.3 XML commands
Description
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.
Optional
Number of times the reader repeated
commands attempting to obtain correct
data.
"0" corresponds to no attempt.
The maximum number of attempts is
set using the WBM.
Optional
Number of times the reader repeated
air interface commands attempting to
obtain correct data.
"0" corresponds to no attempt.
The maximum number of attempts is
specified in the reader firmware and
cannot be modified.
Optional
Indicates whether or not a filter criteri-
on was received.
True:
No problem All the data was read
or there was no filter set.
False:
Data could not be read.