Log settings
In the "Log settings" area, you can use the check boxes to decide which events are entered
in the log. The log is structured as a circular buffer. Remember that a higher degree of detail
for the data can have a negative effect on the computing power of the device.
Table 6- 3
Parameter
General
COMMON
ERRORS
GPIO
FILTER
COMMANDS
EVENTS
Additional information
Return value
Call parameters
Extended acquired
values
Service
CMD_XML
CMD_PLC
CMD_WEB
UHF_LOGIC
Misc
The "Misc" area contains various general reader parameters.
Table 6- 4
Parameter
Expected number of
transponders
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Description of the parameters of the log
Description
Messages relating to general events:
e.g. reader startup, login to the WBM, ...
Error and alarm messages of the reader
Changes to the digital inputs/outputs
Transponders that were filtered out.
Commands of the user application
Recording of all tag events
Return values for the commands of the user application and for the written or
read transponder data.
Call parameters for the commands of the user application
Additional data obtained when the transponder was identified (antenna, polari-
zation, channel, ...).
Frames on the XML interface
Internal frames on the PLC interface
Internal frames between Web server and reader
Internal frames to the UHF part of the reader
Description of the parameters
Description
The number of transponders expected to be read with the reader. With this
input, the reader can optimize the transponder identification.
Value range
Increment
Configuring with the WBM
6.3 The menu items of the WBM
1 ... 1000