Service and maintenance
9.3 Module replacement
Requirement
● The "PROFINET interface [X1]" entry contains the correct IP address of the reader.
● The user name and corresponding password have been entered correctly.
● The entered user has the required rights to run the download/upload (refer to the section
"The "User management" menu item (Page 87)").
Note
User name and password only necessary if user management is enabled
The "User name" and "Password" text boxes only need to be completed if the user
management of the WBM is enabled.
Following the upload/download the status bar indicates whether or not the action was
successful.
Figure 9-4
Backup on your PC
On the upper toolbar of the WBM, there are two buttons for loading and saving
configurations. Using these buttons, you can back up configurations, re-load them and
transfer them to other readers. You will find further information on saving and loading the
configuration on or from the PC in the section "The WBM (Page 35)".
Note
Loading a configuration
Note that you cannot transfer any user profiles and passwords to other readers using the
configuration file. After loading the configuration file on a new reader, you need to enable
user management and create new user profiles and passwords.
242
Successful upload of the configuration
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03