Siemens SIMATIC RF650R Configuration Manual page 79

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Table 6- 22
Property
EPC ID
Antenna
Min. power
Power
RSSI min.
RSSI max.
Acquisition cycles
Date/time
RSSI graph
The graph shows the course of the measured radiated power(dBm value) of the selected
antenna over time (black line) and the RSSI values of all selected transponders (colored
lines/dots). Using the icons, you can modify the display of the graph and adapt it to your
needs.
Table 6- 23
Icon
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Displayed properties of the recognized transponders
Description
/
Selection of the transponders to be displayed in the graph.
Up to 10 transponders can be selected. The selected transponders are shown
in the RSSI graph as continuous lines. Up to 10 further transponders from the
list are displayed as dots.
/
/
Filter status of the transponders
Transponder was identified and returned to the user application.
Transponder was identified but filtered out. Place the mouse pointer over
the symbol to find out which filter filtered out the transponder.
Transponder was identified and not filtered out. However the transponder
has not yet been returned to the user application (e.g. due to the
"Glimpsed" status).
ID of the identified transponder
Antenna with which the transponder was detected.
Minimum radiated power [dBm] of the antenna with which the transponder was
identified.
Radiated power [dBm] of the antenna with which the transponder was last
identified.
Minimum RSSI value of the transponder. Calculated over all successful inven-
tories.
Maximum RSSI value of the transponder. Calculated over all successful inven-
tories.
Number of inventory replies (scans) of this transponder.
Time stamp when the transponder was identified the first time.
Buttons of the RSSI graph
Description
Show/hide grid lines
Change RSSI curve types
Measured values are joined together either with a direct line or using horizon-
tal and vertical lines.
Change over the background color, between white and black
Make RSSI graph moveable / fixed
The RSSI graph is either fixed or the zero point of the graph can be moved
holding down the left mouse button.
Highlight RSSI measured values
Display measured values with thin or thick points.
Configuring with the WBM