Overview of the configurable properties

To display the reader properties, select the reader in the device view and open the
"Properties" tab.
Figure 5-1
The following table provides an overview of all configurable reader parameters:
Table 5- 1
Configurable parameters of the reader
Parameter
General
PROFINET interface [X1]
General
Ethernet addresses
Advanced options
Hardware identifier / diagnostics
addresses
Web Based Management
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Properties of the reader
Functionality
General settings of the reader
All settings of the PROFINET interface
Name of the PN interface
Setting of the IP address and device name
Advanced PROFINET options such as update time, port settings, belonging to
an MRP domain etc.
Hardware identifier of the PROFINET interface (with a connected S7-1200/-
1500).
Diagnostics address of the PROFINET interface (with a connected S7-300/-
400).
Starting the WBM of the reader
Note: The WBM can only be started if either the PROFINET connection between
the CPU and reader is established or the reader was assigned the IP address
stored in the project. This means that the device name has been assigned and
the TIA configuration must be loaded on the SIMATIC controller.
Configuration via STEP 7 (PROFINET device)
5.3 Overview of the configurable properties