Parameter
value_inventoried
Value_
filterDataAvailable
8.3.3.7
writeTagID
This command writes a new EPC-ID to the transponder. To ensure clear identification when
writing the ID, there must be only one transponder in the antenna field. If there is more than
one transponder in the antenna field, a negative reply is returned.
Command
<frame>
<cmd>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Type
Decimal value
0...9
Fixed values
<id> value_id </id>
<writeTagID>
<sourceName> value_sourceName </sourceName>
<tagID> value_tagID </tagID>
<newID> value_newID </newID>
<idLength> value_idLength </idLength>
<password> value_password </password>
</writeTagID>
Values
Description
0...65535
Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-
tus.
True
Optional
False
Indicates whether or not a filter criteri-
on was received.
True:
•
All the data was read or there was
no filter set.
False:
•
Data could not be read.
// opt
// opt
// opt
XML interface
8.3 XML commands
181