Siemens SIMATIC RF650R Configuration Manual page 171

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Reply
<frame>
<reply>
</reply>
</frame>
// opt → Optional: Line can be omitted.
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 211)".
Parameter
Parameter
value_id
value_
sourceName
value_tagID
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
<id> value_id </id>
<resultCode> 0 </resultCode>
<getBlacklist>
<returnValue>
<tagID> value_tagID </tagID>
...
<tagID> value_tagID </tagID>
</returnValue>
</getBlacklist>
Type
Decimal value
0...9
Text
Hexadecimal
value
0...9, A...F
Values
Description
0...4294967295
Unique command identifier
--
Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 46)").
In the standard configuration, there is
only one read point with the name
"Readpoint_1".
--
EPC-ID in "RAW Hex Data Format"
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
XML interface
8.3 XML commands
// opt
// opt
171