Configuration via STEP 7 (PROFINET device)

5.2 The TIA Portal (STEP 7 Basic / Professional)

8. In the next dialog, click the "Continue" button to start the installation.
At the end of the installation, a message appears indicating that the installation was
successful.
9. Click the "Finish" button and restart the TIA Portal.
Result: Your hardware catalog has now been updated in the TIA Portal. If you open the
"Detailed information" dialog again, the "Installed" column for the HSP file now has the entry
"Yes". You will find the RF680R/RF685R readers on the following path in the hardware
catalog: "Detecting & Monitoring > Ident systems > PROFINET > SIMATIC RF600".
As an alternative, you can also link the GSDML file into the TIA Portal. You then install using
the "Options > Install general station description file (GSD)" menu command. When installing
using the GSDML file, you will find the RF680R/RF685R readers on the following path in the
hardware catalog: "Additional field devices > PROFINET IO > Ident systems > Siemens AG
> SIMATIC RF600".
You will find further information and help on linking in files in the online help of the TIA Portal.
5.2
The TIA Portal (STEP 7 Basic / Professional)
The RF680R/RF685R readers can be linked into SIMATIC automation systems using STEP
7 Basic / Professional as of V13 (TIA Portal). The connection is via PROFINET. Following
this, you can configure the reader using the WBM while you control the work with the reader
using the Ident library of the TIA Portal.
Requirement
The reader is connected, has started up and a device name has been assigned to the
reader. The TIA Portal has been started.
Procedure
Follow the steps below to create a new project:
1. Call up the TIA Portal with "Start > All Programs > Siemens Automation > TIA Portal Vxx".
2. Create a new project.
3. Change to the Project view.
4. Using the project tree, insert a SIMATIC controller in the project using the "Add new
device" menu command.
The device view opens and the SIMATIC controller is displayed.
5. Drag the required reader type from the hardware catalog to the project ("Detecting &
Monitoring > Ident systems > PROFINET > SIMATIC RF600").
6. Change to the network view and connect the reader to the SIMATIC controller.