Interface to the SIMATIC controller
7.6 Programming Ident blocks
Figure 7-11
Table 7- 7
Parameter
ATTRIBUTE
DURATION
DUR_UNIT
IDENT_DATA
110
"Inventory" block
Explanation of the "Inventory" block
Data type
Byte
Word
Word
Any / Variant
Default values
Description
B#16#0
Selecting the status mode
0x80 ≙ EPC-ID without additional
information
0x81 ≙ EPC-ID with additional
information on the RSSI value and
reserved bytes
0x86 ≙ enable Presence mode
0x87 ≙ disable Presence mode
W#16#0
Duration dependent on "DUR_UNIT"
Period of time or number of invento-
ries or number of "Observed" events
Example:
0x00 ≙ no inventory or 0 ms
0x01 ≙ one inventory or 1 ms or
one transponder
W#16#0
Unit for "DURATION"
0x00 ≙ time [ms]
0x01 ≙ inventories
0x02 ≙ number of "Observed"
events
0
Data buffer for inventory data
Note:
For Variant, an "Array_of_Byte" with a
variable length and the existing status
UDTs can be created. For Any, other
data types/UDTs can also be created.
Configuration Manual, 10/2015, C79000-G8976-C386-03