XML interface
8.4 XML EventReports
8.4.2

Interrupts

This section describes all alarms. Alarms are asynchronous messages and are used as
status, warning or error messages of the reader.
The meaning of an alarm is indicated by the error number and other optional parameters.
Report
<frame>
<alarm>
</alarm>
</frame>
// opt → Optional: Depending on the parameter assignment or the amount of data, the line
can be omitted.
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 211)".
222
<id> value_id </id>
<error>
<utcTime>value_utcTime </utcTime>
<errorNumber>value_errorNnumber </errorNumber>
<errorText>value_errorText </errorText>
<eventType>value eventType </eventType>
<paramXY>value_param_xy </paramXY>
...
</error>
<id> value_id </id>
<resultCode> 0 </resultCode>
<error/>
// opt