Danfoss Vacon NXP Series Operating Manual page 58

Air-cooled wall-mounted and standalone
Hide thumbs Also See for Vacon NXP Series:
Table of Contents

Advertisement

Operating guide | VACON® NXS/NXP Air-cooled
Procedure
1. Strip the motor cable, the mains cable, and the brake resistor cable. See
2. Cut the grommets open to move the cables through them. Use the grommets delivered in the accessories bag.
Do not cut the grommet openings wider than what is necessary for the used cables.
If the grommets fold in when putting the cable, pull the cable back to make the grommets straight.
Use a grommet as an alternative to the grommet in types where this is necessary.
3. Put the cables - the mains cable, the motor cable, and the optional brake cable - in the openings of the cable entry plate. Use the
cable entry plate delivered in the accessories bag.
A
B
A The mains cable
C The motor cable
Illustration 21:
4. Put the cable entry plate with the cables into the groove on the frame of the drive. To attach the cable entry plate, use the M4x10
screws delivered in the accessories bag.
58 | Danfoss A/S © 2018.06
C
Cables through the Cable Entry Plate
12.4 Cable Stripping
Lengths.
B The brake cable
Electrical Installation
DPD00910G