CDM-625 Advanced Satellite Modem
Introduction
1.7.8

Miscellaneous

Front Panel
Loopbacks
Fault relays
M&C Interface
M&C Software
Firmware update
Dimensions
Weight
AC consumption
AC operating voltage
DC consumption
(option)
DC operating voltage
Operating temperature
1.7.9

Approvals

"CE" as follows:
FCC
Tactile keypad, 6 keys (Up/Down), Left/Right, Enter/Clear)
Vacuum Fluorescent Display (blue) – 2 lines of 40 characters
Internal IF loopback, RF loopback, digital loopback, and inward/outward loopback
Hardware fault, Rx and Tx Traffic Alarms, Open Network Backward Alarms
Type: Form C Contacts. Rating: Up to +/-50 volts, max 0.5 Amp
EIA-232 and EIA-485 (addressable multidrop, 2-wire or 4-wire) or Ethernet (10/100
BaseT)
Serial comms, SNMP, Telenet, Web Server (http)
Via Ethernet port. ftp protocol
1RU high, 17.65 inches (448 mm) deep
10.5 lbs (4.8 kgs) max (All option cards and 48V BUC supply installed)
48 watts (typical, TPC/LDPC Codec and CnC module installed), 55 watts (maximum)
280 watts (typical TPC/LDPC Codec, CnC module and 48 volt BUC supply installed,
300 watts (max)
100 - 240 volts AC. +6%/-10% - autosensing
(total absolute max. range is 90 - 254 volts AC)
As above (AC consumption)
48 volts nominal
(total range is 36 - 60 volts)
0 to 50ºC (32 to 122ºF)
EN 55022 Class B
(Emissions)
EN 50082-1 (Immunity)
EN 60950 (Safety)
FCC Part 15 Class B
MN-0000036 (Ref MN/CDM625.IOM)
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-4
EN 61000-4-5
1–21
Revision 1
EN 61000-4-6
EN 61000-4-8
EN 61000-4-9
EN 61000-4-11
EN 61000-4-13