CDM-625 Advanced Satellite Modem
Ethernet Management
6.5.4.3.6
Config | BUC (Block Up Converter)
The 'Config | BUC' page (Figure 6-11) is used to configure Block Up Converter parameters, and
display the BUC status for L-Band operation.
BUC Configuration
BUC Power Enable, 10 MHz Ref Enable, and Output Power Enable may be turned
•
ON or OFF.
•
The user may assign BUC Low and High Current Limit values ranging from 0 to 4000
mA.
•
The user may assign the Tx Lockout Frequency and designate the value as a HIGH (+)
or LOW (-) limit.
•
The user may assign a BUC Address of 0 to 15.
BUC Status
The parameters shown here are read-only and cannot be changed.
Once the desired configuration settings have been made on this page, the user should then click
[Submit BUC Controls] as needed to save those changes.
Figure 6-11. Config | BUC page
6–19
MN-0000036 (Ref MN/CDM625.IOM)
Revision 1