CDM-625 Advanced Satellite Modem
Front Panel Operation
5.10.1.2
ODU: BUC:PwrSupply+Ref
BUC-LO Frequency= 00000 MHz
This menu permits the user to enter the BUC LO frequency for the up conversion. Entering a non-
zero value for BUC LO will cause the Tx-IF frequency menu to show LO and Satellite frequencies.
The Mix sets the polarity for the upconversion mix in the BUC:
•
•
Satellite frequency = LO frequency +/- modem frequency.
Select the parameter to edit using the
MHz; the available options are shown in parentheses. Use the
then press ENTER when done.
5.10.1.3
ODU: BUC:PwrSupply+Ref
BUC Power Supply:
This display shows the power supply current and voltage information. Press ENTER or CLEAR
to return to the previous menu.
5.10.2 ODU: LNB:PwrSupply+Ref (Power Supply and Reference)
LNB control/monitor:
PSU-and-10MHz
The modem can supply DC power to an LNB connected to the Rx N-type connector. It can also
supply a 10MHz reference for a phase-locked LNB.
5.10.2.1
ODU: LNB:PwrSupply+Ref
LNB: Voltage=Off
Alarm limits, from 000 t0 500 mA
Select the parameter to edit using the
or 24V. The other available options are shown in parentheses. Use the
setting, then press ENTER when done.
Mix= High [-] (Hi,Lo)
High indicates a high side, inverting mix;
Low indicates a low side, non-inverting mix.
◄ ►
0000mA, 00.0V
LO-freq
◄ ►
LO Frequency
arrow keys. The valid LO range is 3000 to 65000
▲ ▼
PSUmonitor
PSUmonitor (34)
PSU and 10 MHz
10MHz:Off (Off,On)
arrow keys. The Voltage options are: Off, 13V, 18V,
5–62
MN-0000036 (Ref MN/CDM625.IOM)
(34v)
arrow keys to edit the setting,
(34v)
arrow keys to edit the
▲ ▼