Current Utilization Of The Drive Motors - HEIDENHAIN iTNC 530 Service Manual

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

The I
equal to 0 are in the F-DC, T-DC, F-AC and T-AC columns of the motor or power module tables.
If the value 0 is entered in these columns, the following default values are valid:
In the power module table, all HEIDENHAIN inverters whose names do not end in "...-QAN"
or "...-QSY" have entries in these columns.
MP2302.x
Input:
MP2304.x
Input:
Possible
No claim for completeness; contact your machine manufacturer!
causes of error
If possible, write your own experience!

9.3.9 Current Utilization of the Drive Motors

Module 9166 provides the momentary utilization of the given drive motor as a percentage value.
Ask your machine tool builder whether this PLC module is evaluated and how the information is
displayed.
May 2006
2
t monitoring according to the temperature model above can only be used if entries not
Axis drives:
F-DC = 0
T-DC = 10
F-AC = 0
T-AC = 10
Spindle drives:
F-DC = 0
T-DC = 150
F-AC = 0
T-AC = 150
Reference value for I
0 to 1 000.000 [· rated current of motor]
2
0: I
t monitoring of the motor switched off
1: Rated current of motor as reference value
Reference value for I
0 to 1 000.000 [rated current of power module]
2
0: I
t monitoring of power module switched off
1: Rated current of power module as reference value
Overload of drives (power module, motor)
Axis traverses as far as it will go
Mechanical stiffness
2
t monitoring of the motor
2
t monitoring of the power module
9 – 67