Signal
I2-t (p.m.)
Utilization
Block number
Gantry Diff
U nominal
P mech.
P elec.
M actual
S noml (f.)
DSP debug
Contour dev.
F TCPM
Int. diagn.
The recorded data remain stored until you start recording again or activate another graphic
function.
8.2

Setup

The setup menu appears:
8 – 50
Meaning
Current value of I2-t monitoring of the power module (%)
Actual utilization of the drive (%)
Block numbers of the NC program
Difference between synchronized axes (mm)
Nominal voltage (V)
Mechanical power (W)
Electrical power (W)
Actual torque value (Nm)
Nominal position after nominal position value filters (mm)
Diagnosis function for internal purposes
Circular interpolation test, contour deviation (mm)
Feed rate for the tool point with TCPM
Reserved for internal purposes
Activate the oscilloscope as follows:
Programming and Editing --> MOD key
--> soft keys DIAGNOSIS --> DRIVE DIAGNOSIS --> OSCI
or with the code number 688379
Choose the parameters to be entered with the cursor keys.
Open the selection window with the GOTO key.
Use the cursor to select a value and confirm it with the ENT key.