By means of W494 the function of the feed-rate override potentiometer, and by means of
W492 the function of the spindle override potentiometer can be controlled:
May 2006
Press EMERGENCY STOP.
Activate the HR 420 (press the handwheel symbol on the HR 420).
Activate the handwheel potentiometers (as of NC software version 34049x-xx).
Call the PLC table with the words. --> see "The TABLE Function" on page 10 – 76.
Select the decimal display.
Turn the potentiometer to be investigated.
The value of W492 or W494 changes between 0 and 10000 with nonlinear or between 0
and 100 with linear curve of the potentiometer (the curve is defined in MP 7620 bit 3).
Note
These PLC words can also be shown in the integrated oscilloscope.
--> see "Checking the Potentiometers" on page 22 – 364.