Assignment of the
The tables below list the assignments of switch positions of S1 and S2 to the
switch positions to
PLC inputs I160 to I175.
the PLC inputs
The two switches work with a 0 V logic circuit.
Example:
If switch S1 is in position 3, input I162 is logically 0, and all other inputs
are logically 1.
Step switch 1: Step switch for choosing the interpolation factor
Switch position
1 (at the left stop)
2
3
4
5
6
7
8 (at the right stop)
Step switch 2: Axis selection switch
Switch position
1 (at the left stop)
2
3
4
5
6
7
8 (at the right stop)
May 2006
PLC input
I160
I161
I162
I163
I164
I165
I166
I167
PLC input
I168
I169
I170
I171
I172
I173
I174
I175