Checking The Potentiometers - HEIDENHAIN iTNC 530 Service Manual

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

22.5 Checking the Potentiometers

Potentiometer
You can use the PLC table to determine whether the control receives the potentiometer signal.
values in the
PLC-TABLE
The potentiometer setting is shown in the following PLC words:
Proceed as follows:
Potentiometer
With the integrated oscilloscope you can also record the condition of PLC words.
-> see "Integrated Oscilloscope" on page 8 – 49.
values in the
oscilloscope
The advantage of this method is that possible wiper interruptions of the potentiometers can be
recognized better than in the PLC TABLE.
For this investigation the machine must be switched on completely!
22 – 364
W492 (=S override)
W494 (= F override)
Press EMERGENCY STOP.
Call the PLC table for the words (see "The TABLE Function" on page 10 – 76).
Place the cursor at W492 or W494.
Select the decimal display.
Turn the potentiometer to be examined.
Check if the display can be changed from 0 to 15000 (with nonlinear characteristic curve)
or 0 to 150 (with linear characteristic curve).
The characteristic curve is defined in MP 7620 bit 3.
HEIDENHAIN Service Manual iTNC 530

Advertisement

Table of Contents
loading