Restoring the
After having finished data back-up and separated the connection, do not forget to restore the
original settings
original network settings of your laptop or of the iTNC.
May 2006
Enter the original settings and confirm with ENTER.
Delete the newly inserted line in the network settings of the control. --> The line with the
original settings moves again to the top-most position.
If you have overwritten the original settings on the control, you have to enter them again or
copy the back-up file (e.g., ip4n00.a) to file ip4.n00.
Note
The control has to be rebooted to activate the settings!
Note
You can protect the file ip4.n00 with the original network settings.
Call the PLC partition (PLC code number) and subsequently the program manager. Enter the
folder NET. Move the cursor to the file and press the soft keys AUX. FUNCTIONS.
--> PROTECT. A P is shown in the status column for "protected".