HEIDENHAIN iTNC 530 Service Manual page 491

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

MP
MP2392.x
MP2394.x
MP2396.x
MP2420.x
MP2430.x
MP2500.x
MP2510.x
MP2512.x
MP2520.x
MP2530.x
MP2540.x
May 2006
Function and input
Power limit
Input:0: No power limit
0.1 to 3000.000 [kW]
Max. braking performance at power failure
Input:0.1 to 3 000.000 [kW]
0: Braking power is not limited
Maximum torque
Input:0.1 to 30,000.0 [Nm]
0: Torque is not limited
Proportional factor of the current controller
Input:0.00 to 9999.99 [V/A]
Integral factor of the current controller
Input:0.00 to 9 999.99 [V/As]
Proportional factor of the speed controller
Input:0 to 1 000 000,000 [As]
Integral factor of the speed controller
Input:0 to 100,000,000 [A]
Limiting the integral-action component of the speed
controller
Input:0.000 to 30.000 [s] (realistic values:
0.1 to 2.0)
Differential component of the speed controller
Input:0 to 1.0000 [As]
PT
element of the shaft speed controller (2nd-order delay)
2
Input: 0 to 1.0000 [s]
Band-rejection filter for damping
Input:0.0 to 18.0 [dB]
Behavior/
SW vers.
PLC
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
30 – 491