6.3

Overview of Log Entries

Entry
RESET
ERR
INFO
INFO
KEY
INFO
a
STIB
INFO
INFO
INFO
INFO
a. Control-in-operation symbol = "* " in the screen display
May 2006
MAIN ERRCLEARED
MAIN ERR_RECURED
MAIN SOFTKEY
ON
OFF
BLINK
MAIN START
MAIN FILE DEL
MAIN CYCLES
MAIN KEYSOURCE
Description
Restart of the control
Error Messages
P --> PLC error message with line number in the
PLC error text file
N --> NC error message with number
Power fail interrupt ! --> Control is switched off by
a POWERFAIL
Result of the file system test:
If the control is not properly shut down, the file
system is checked during the next startup and the
result is entered in the log.
--> Search in the log for "dosfsck -a"
Confirmation of an error message
Error message entered several times
Key strokes
Path with appropriate image file of a pressed soft key
"Control-in-operation" on
"Control-in-operation" off
"Control-in-operation" blinking
Control model and NC software
Faulty files on the hard disk, to be erased during
booting
Test results for fixed cycles and touch probe cycles
Source of the keystrokes
KEYBOARD
PLC
PLCNCSTART
HANDWHEEL
LSV2
6 – 37