HEIDENHAIN iTNC 530 Service Manual page 493

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

MP
MP2562.x
MP2563.x
MP2564.x
MP2565.x
MP2566.x
MP2572.x
MP2573.x
MP2574.x
MP2575.x
MP2576.x
MP2590.x
MP2600.x
May 2006
Function and input
Only CC 424: Filter type for filter 1
Input:0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
Only CC 424: Filter type for filter 2
Input:0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
Only CC 424: Filter type for filter 3
Input:0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
Only CC 424: Filter type for filter 4
Input:0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
Only CC 424: Filter type for filter 5
Input:0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
Only CC 424: Band width of the band-rejection filter for filter
1
Input:0 to 30000.0 [Hz]
Only CC 424: Band width of the band-rejection filter for filter
2
Input:0 to 30000.0 [Hz]
Only CC 424: Band width of the band-rejection filter for filter
3
Input:0 to 30000.0 [Hz]
Only CC 424: Band width of the band-rejection filter for filter
4
Input:0 to 30000.0 [Hz]
Only CC 424: Band width of the band-rejection filter for filter
5
Input:0 to 30000.0 [Hz]
Braking ramp in an emergency stop
Input:0.1 to 999.9 [min
0: Function inactive
Acceleration feedforward control
Input:0 to 100.0000 [A/(rev/s)]
Behavior/
SW vers.
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
–1
/ms]
RUN
PLC
30 – 493