The ERR window is described below:
Column
Number
Class
Group
Error
message
The individual error messages can be selected with the cursor; the open help window shows
the appertaining text.
4.4

CE Key

Displayed error messages can be acknowledged with the CE key.
If the error cause is still existing, the corresponding error message is displayed again.
--> Eliminate the error!
May 2006
Description
Error number that was defined by HEIDENHAIN or the machine manufacturer
(-1: No error number defined)
Error class. Defines the reaction of the control:
ERROR
Program run is interrupted by the TNC (INTERNER STOP)
FEED HOLD
The feed rate enable is deleted
PGM HOLD
The program run is interrupted (control-in-operation symbol blinking)
PGM ABORT
The program run is aborted (INTERNER STOP)
EMERG. STOP
EMERGENCY STOP is generated
RESET
TNC executes a warm start
WARNING
Warning message, program run is continued
INFO
Info message, program run is continued
Error source.
GENERAL
General error
OPERATING
Error during machining and machine traverse
PROGRAMMING
Error during programming
PLC
PLC error message of the machine manufacturer
Displayed error text
Delete the error message
Note
Messages regarding very fatal errors, cannot be confirmed with the CE key.
The control must be rebooted.--> Press the END key.
If this does not function ... --> Switch the power switch of the machine off and on again.