28 – 454
The currently used software version is distinguished by a asterisk.
Place the cursor to the marked NC software version!
Caution
You may only activate the NC software currently used by the machine!
It is marked with an "*."
If further NC software versions are shown in the selection window shown, they could be
selected. This is only possible after prior consultation with the machine manufacturer as ...
The NC software must be released by the machine manufacturer.
Manufacturer cycles are no longer displayed.
Cutting-data, workpiece-material tables, etc. could be overwritten.
Machine parameters may be added or are not active any more.
Press the SELECT soft key .
Confirm your selection with the YES soft key.
Note
If now the error message Not enough space on SYS: is generated, one or several packed
NC software versions must be deleted from the SYS partition. --> Ask the machine
manufacturer!
The control activates the selected NC software again and performs a reset.
Call the machine parameter list with the corresponding code number.
Now press the MOD key.
Press the UPDATE DATA soft key.
Press the ASC-->BIN soft key to convert the files on the hard disk from binary to ASCII
format.
The activation of the NC software is completed.
Caution
The service pack used so far must now be installed again.
--> see "Loading of Service Packs" on page 27 – 443!
Finally, check the machine functions!