HEIDENHAIN iTNC 530 Service Manual page 495

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

MP
MP2910.x
MP2920.x
MP2930.x
May 2006
Function and input
P factor of the torque controller for master-slave torque
control (entry for the slave axis)
Input:0.00 to 999.99 [1/(Nm ⋅ min)]
Factor for variable torque distribution of the master-slave
torque control
(entry for the slave axis)
Input:0 to 100,000
1: Master and slave axes have identical motors
Speed compensation ratio for master-slave torque control
(entry for the slave axis)
Input:-100.00 to +100.00 [%]