MP
MP2250.x
MP2252.x
MP2254.x
MP2256.x
MP2257.x
MP2302.x
MP2304.x
MP2308.x
MP2312.x
MP2390.x
30 – 490
Function and input
Only CC 424: Determining the field angle without motor
motion
Input:0: Same as input value 2
1: reserved
2: Method 2 (brakes applied)
3: Method 3 (same as Method 2, but motor
brake is not applied)
Only CC 424: Reserved
Input:Enter 0
Determining the field angle
Input:0: Field angle is determined during
operation; soft key has no function (without plau-
sibility test)
1: Only CC 422: Field angle is determined via soft
key; motor motion is permitted
2: Only CC 424: Field angle is determined via soft
key; motor motion is permitted (with plausibility
test)
Determined field angle
Input:0: Field angle does not need to be
determined, or has not been determined
Control or encoder identification for the field angle from
MP2256.x
Input:0: Field angle does not need to be
determined, or has not been determined
2
Reference value for I
t monitoring of motor
Input:0 to 1000.000 [⋅ rated current of
motor]
2
0: I
t monitoring of motor switched off
1: Rated current of motor as reference value
2
Reference value for I
t monitoring of power module
Input:0 to 1000.000 [⋅ rated current of
power module]
module switched off
1: Rated current of power module as reference
value
Time between output of the braking signal BRK and
switching off of the controller (overlap time)
Input: 0.001 to 0.500 [s]
0: 0.200 s
Factor for utilization of motors
Input:0 to 1,000.000
0: Factor = 1
Maximum braking power
Input:0.1 to 3 000.000 [kW]
0: Braking power is not limited
2
0: I
t monitoring of power
HEIDENHAIN Service Manual iTNC 530
Behavior/
SW vers.
340 422-03,
340 480-03
PLC
RUN
340 422-03,
340 480-03
PLC
RUN
340 420-09
PLC
RUN
340 422-03,
340 480-03
PLC
RUN
340 422-03,
340 480-03
PLC
RUN
340 420-06
340 420-06