Soft keys within the SELECT + COMPILE function:
Soft key
E.g. to compile any desired PLC program:
The name and path of the compiled PLC program PLCMAIN= are entered in the OEM.SYS.
With the COMPILE PLC-MAIN PROGRAM soft key the PLC program is now compiled from
this entry.
10 – 90
Soft key to call the SELECT + COMPILE function
Function
Select and compile the configuration file for the compilation of
source code
Select and compile a PLC program
Select and compile a PLC error table
Select and compile a soft-key project file
Select and compile a magazine rule file
Returns to the PLC main menu
Press the SELECT + COMPILE soft keys
Press the SELECT PLC-MAIN PROGRAM soft key
Use the arrow keys to select the PLC program to be compiled
Press the ENT key
Caution
Only the main program may be converted.
If a subprogram was accidentally compiled instead of the PLC main program, the error
message PLC program not translated is generated. In this case the compiler has detected
global modules in this file.
In a main PLC program there are no modules defined as "global".
It is possible that the error message PLC: global in the main file is also displayed, which
indicates that a subprogram was compiled instead of the main PLC program.