Lucent Technologies CBX 3500 Configuration Manual page 836

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Reliable Scalable Circuit
Circuit Add Errors
Table F-1. Errors Encountered During Circuit Add Procedure (Continued)
Type of Failure
Standard PVC – Circuit not
present on 1st switch
(lower-numbered node)
Redirect PVC – Circuit not
present on the Primary or
Secondary switch
Standard PVC – Circuit not
present on 2nd switch
(higher-numbered node)
Redirect PVC – Circuit not
present on the Pivot switch
F-41/19/05
SNMP Set Failure Reason
There is no such variable name
in this Management
Information Base (MIB);
possibly the card is down or
not present
(specific endpoint not
identified).
There is no such variable name
in this MIB; possibly the card
is down or not present
(specific endpoint not
identified).
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Beta Draft Confidential
Abort – Discontinue attempt to add circuit
(NMS database unmodified, nothing
marked out-of-sync). PRAM sync of
endpoint cards will remove traces of
circuit from switches.
Retry – Attempt to add the circuit again.
Dangling circuit on 1st (or Primary or
Secondary) switch will not interfere with
the Retry.
Abort – Discontinue attempt to add circuit
(NMS database unmodified, circuit
dangling on 1st [or Primary or Secondary]
switch; nothing marked out-of-sync).
PRAM sync of endpoint cards will remove
traces of circuit.
Retry – Attempt to add the circuit again.
Dangling circuit on 1st (or Primary or
Secondary) switch will not interfere with
the Retry.
Available Choices