Lucent Technologies CBX 3500 Configuration Manual page 682

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Configuring SPVCs
Defining a Point-to-Point Offnet Circuit Connection
Table 18-6. Add Offnet Circuit: Traffic Type Tab Fields (Continued)
Priority (for
Forward and
Reverse)
(VBR-NRT and
VBR-RT QoS
classes on
CBX/GX only)
Traffic
Descriptor:
Type
18-181/19/05
Field
From the pull-down menus, select both the forward and reverse circuit
priority values. 1 is high priority, 2 is medium priority, 3 is low priority,
and 4 is lowest priority. (For a B-STDX endpoint, the priority range is
from 1 – 3 only.) The forward and reverse circuit priority values do not
have to match. CBR QoS class priority is set to 1.
Note: This is applicable for VBR-RT and VBR-NRT classes only. This
field will be grayed out for CBR, UBR, and ABR classes.
Select, from the pull-down menu, one of the following TD options:
PCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes PCR CLP=0. If so, specify the peak cell rate
(PCR) in cells per second (CS) for high-priority traffic (that is, the
CLP=0 cell stream).
PCR CLP=0+1 (cells/sec) – Specify the PCR in CPS for the combined
high- and low-priority traffic (that is, the CLP=0+1 aggregate cell
stream).
SCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes SCR CLP=0. If so, specify the sustainable
cell rate (SCR) in CPS for the combined high-priority traffic (that is,
the CLP=0 cell stream).
SCR CLP=0+1 (cells/sec) – Displays only if you selected a TD
combination that includes SCR CLP=0+1. If so, specify the SCR in
CPS for the combined high- and low-priority traffic (that is, the
CLP=0+1 aggregate cell stream).
MBS CLP=0 (cells) – Displays only if you selected a TD combination
that includes MBS CLP=0. If so, specify the maximum burst size
(MBS) in CPS for the combined high-priority traffic (that is, the
CLP=0 cell stream).
MBS CLP=0+1 (cells) – Displays only if you selected a TD
combination that includes MBS CLP=0+1. If so, specify the MBS in
CPS for the combined high- and low-priority traffic (that is, the
CLP=0+1 cell stream).
MCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes MCR CLP=0. If so, specify the minimum
cell rate (MCR) in CPS for the combined high-priority traffic (that is,
the CLP=0 cell stream).
Although the MCR TD is only applicable to a CBX 500 with an FCP,
this attribute is offered as a selection on non-CBX endpoints. This is
because even though one or both endpoints may not be on a CBX with
FCP, the PVC might traverse a CBX 500 FCP trunk. In this case, the
provisioned attribute is used.
Note: On ATM circuit emulation (CE) endpoint(s), the PCR, SCR, and
MCR CPS values default to 118980 and cannot be changed.
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Beta Draft Confidential
Action/Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbx 500Gx 550B-stdx 9000

Table of Contents