Configuring SPVCs
Defining a PMP SPVC (Offnet Circuit)
Table 18-10. Add Offnet Point-to-Multipoint PVC Root: Traffic
QoS Class
(Forward or
Reverse
direction)
Traffic
Descriptor: Type
(Forward and
Reverse
direction)
PCR (cells/sec)
3. When the Traffic Type attributes have been configured, continue with
Completing the Offnet PMP PVC Root Configuration
Use the following steps to complete the circuit configuration.
1. (Optional) To configure CBX 500 or GX 550 Network Data Collection (NDC)
2. (Optional) To configure NavisXtend Accounting Server parameters for this
3. (Optional) To manually define the circuit path for this circuit, select the Path tab.
4. Choose OK to create the new offnet circuit root. Continue with
18-361/19/05
Type Tab Fields
Field
Select one of the following QoS values from the pull-down list:
CBR – Used for applications that are represented by a continuous bit
stream, such as video and digitized voice. CBR traffic requires
guaranteed throughput rates and service levels.
VBR (Real Time) – Used for delay-sensitive applications, such as
packet video, that require low cell delay variation between endpoints.
VBR (Non-Real Time) – Used to transfer long, bursty data streams over
a pre-established ATM connection. It is also used for short, bursty data
such as LAN traffic. CPE protocols adjust for any delay or loss
incurred.
UBR – Used primarily for LAN traffic. The CPE should compensate
for any delay or lost cell traffic.
Note: UBR is used only with the ATM FCP.
Select the TD that you want to specify. The available selections will
depend on the QoS class you choose.
See
Chapter 12, "Configuring ATM Traffic Descriptors"
information on TD types.
Enter the PCR in CPS for the circuit. The availability of this field will
depend on the QoS class you choose.
"Completing the Offnet PMP PVC Root Configuration."
parameters for this circuit, select the NDC tab. For more information, see the
Switch Diagnostics User's Guide
circuit, select the Accounting tab. For more information, see the NavisXtend
Accounting Server Administrator's Guide.
See
"Manually Defining the Circuit Path" on page 10-68
PMP Leaves" on page 18-37
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Beta Draft Confidential
Action/Description
for CBX 3500, CBX 500, GX 550, and B-STDX 9000
to create the offnet circuit leaves.
for more
for more information.