Lucent Technologies CBX 3500 Configuration Manual page 345

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Beta Draft Confidential
Table 8-13. Add Trunk: Administrative Tab (Continued)
Static Delay (in
microsec)
Dynamic Delay (in
microsec)
8. When you finish defining the trunk attributes, choose OK to complete the trunk
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Field
Represents the measured one-way delay in units of 100 msecs.
This measurement is taken when the trunk initializes and it is
only updated when the trunk state changes from down to up. The
static delay value is used in conjunction with the end-to-end
delay routing metric to enable you to route circuits over trunks
with the lowest end-to-end delay.
Represents the measured one-way delay in units of 100 msecs.
This measurement is made continually on operational trunks.
Under most conditions, the dynamic delay value will match the
static delay value. However, if some characteristics of the
underlying transmission media for the trunk changes, such that
the dynamic delay changes, this value may differ from the static
delay.
configuration.
Configuring ATM Over MPLS Trunks
Configuring the ATMoMPLS Trunk
Action/Description
1/19/058-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbx 500Gx 550B-stdx 9000