Configuring CBX or GX Logical Ports
Setting Logical Port Attributes
3-401/19/05
Table 3-6. Add Logical Port: CES Parameters Tab Fields (Continued)
Field
Max Cell Jitter (10
The maximum cell arrival jitter in 10
µ
secs)
reassembly process can tolerate without producing errors. The
default is 100
Max Cell Loss
The maximum number of cells inserted when cell loss occurs.
(1-7)
The maximum value for this field is 7. The default value is 1.
Note: When the number of cells lost exceeds this value, the AAL1
chip goes into an under-run condition.
Insert Cell Field
Enter the value for the inserted cells when User Defined is
(0-11)
selected as the Insert Cell Type. The range is zero (0) to 255.
Partial Cell Value
Enables partial cell fill and specifies the minimum partial cell
(1-47)
size. It can be used to minimize the amount of delay required to
assemble a cell.
Note: The Partial Cell Value must be 1 greater than the number
of configured DS0s. However, if the number of configured DS0s is
greater than 16, then the Partial Cell Value has to be 2 greater
than the number of configured DS0s.