Configuring SVC Parameters
Configuring SVC Attributes
17-121/19/05
Table 17-3. Configure SVC: Signaling Tab Fields (Continued)
Field
Override Default (for
reverse signaling)
Reverse: PMP Rev, Unsp
CBR
VPCI/VPI Mapping
VPI=VPCI
VPI=VPCI+
VPI=VPCI-
Table
Proxy Signaling
Enable
Proxy Client
(for ATM UNI only)
Use Proxy Agent on LPort
Agent Node Id
Agent Interface Number
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Beta Draft Confidential
Description
Select the check box to override the default TD for
reverse signaling. You can then select a different TD.
Remove the check from the box to use the default
Traffic Descriptor for reverse signaling. You will not be
able to select a different traffic descriptor.
Choose a TD for reverse signaling. This field is enabled
only if you selected the Override Default check box (for
reverse signaling).
Sets mapping to equal. The VPI equals the VPCI.
Sets mapping to positive offset. Text box allows entry
of integer offset. The VPI of the corresponding circuit
equals the VPCI plus the value you enter.
Sets mapping to negative offset. Text box allows entry
of integer offset. The VPI of the corresponding circuit
equals the VPCI minus the value you enter.
Sets mapping to VPCI entry from the VPCI table for
the LPort. This option has additional functions that are
used with Proxy Signaling. For information on
configuring the VPCI table, see
Management VPCI Table Entry" on page
Select the check box to enable proxy signaling for the
SVC.
Choose this button to use the proxy agent for signaling.
Enter the LPort to use as a proxy agent by choosing the
following button:
Then, select an LPort from the list displayed.
The ID of the switch to be used as the proxy signaling
agent.
The agent interface number assigned to the proxy
signaling agent.
"Configuring a
17-16.