Lucent Technologies A500 User Manual
Lucent Technologies A500 User Manual

Lucent Technologies A500 User Manual

Atm switch

Advertisement

Lucent Cajun
TM
TM
A500 ATM Switch
User Guide Release
3.0
Part #: 49080007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lucent Technologies A500

  • Page 1 Lucent Cajun A500 ATM Switch User Guide Release Part #: 49080007...
  • Page 2 Cajun P550, Cajun A500, Lucent Definity ATM ECS, and Lucent MMCX are trademarks of Lucent Technologies. The following products are trademaked by their respective companies: Bay Networks, Cisco, Fore, 3COM, Sun, HP, Compaq, and Microsoft.
  • Page 3 Contents...
  • Page 11 Preface documentation@lucentctc.com http://pubs.lucentctc.com/...
  • Page 12 System Output passwd greyhound Unit 2 Port 2 admin...
  • Page 17 M A K E R ETHER TC P Telnet UD P TFTP LANE CA C...
  • Page 19 P N N I R o u tin g Task ILMI C all C o n tro l Task Task U N I/P N N I S ig n alin g Task S w itch M o n /C trl C h assim o n TA S K Snooping...
  • Page 22 LANE A500 Server Ethernet Management A500 Station Cloud A500...
  • Page 23 Mini-Bridge Local Ethernet VCCs to other A500s 'HVLJQDWHG$ MAC – IP – Port Mapping Table (MIPM) Proxy-ARP Handler «...
  • Page 24 G eneric O perating S ystem Interface O perating S ystem A daptation Layer Tim er M anager B uffer M anager H igh Level I/O Interface O ther M isc F unctions pR O B E + pS O S + D evice D river...
  • Page 25 Process A Process B Network Protocols (e.g., TCP/IP, UDP/IP) lfTxFrame/lfhISR Driver SOCKET Ether Driver...
  • Page 29 R outing U N I M gm t Task Task S ig naling Task C h assim on Task S w itc h M o n /C trl Snooping Task LEGEND Data Control ... L ocal D irect M od em C onsole C onso le Task S N M P...
  • Page 30 ATS0=0...
  • Page 31 TIMEOUT 3 ABORT NO\sCARRIER ABORT BUSY ABORT NO\sDIALTONE \N AT OK ATDT\T CONNECT \N login: \U password:...
  • Page 32 To/From pNA (IP) PPP actually provides NI interface Link Control Protocol Authentication HDLC Serial Port Modem IP Control Protocol Ip Control Protocol PPP provides modem support also in the form of scripts.
  • Page 38 Management Station Separate web server serves on-line help and bitmaps. Switch serves page content and receives responses.
  • Page 40 http://pubs.lucentctc.com/ http://pubs.lucentctc.com...
  • Page 42 System Logs Statistics Virtual Circuits ATM Ports PNNI Signaling...
  • Page 43 Services Clock Sync TFTP...
  • Page 44 AX500: admin address Enter IP Address [198.3.104.162]: 198.3.104.163 Enter IP Mask [255.255.255.0]: 255.255.255.0 New IP Address and Mask will be used when A500 is rebooted modify default gateway AX500: modify default gateway Enter IP gateway[198.3.104.240]:198.3.104.240 Default Gateway will be used when A500 is rebooted.
  • Page 47 admin downInterface admin up...
  • Page 48 admin link_type admin upInterface...
  • Page 49 admin signaling route add admin signaling route remove...
  • Page 50 admin signaling esi add ESI successfully removed admin signaling esi remove...
  • Page 51 modify add_channel point-point command. modify add_channel multipoint...
  • Page 52 modify rem_channel...
  • Page 53 admin lec...
  • Page 54 admin static_ip enable_client admin static_ip enable_server...
  • Page 55 admin static_ip add_client admin static_ip set_server admin pnnilevel...
  • Page 58 sync setsync...
  • Page 59 tftp setserver...
  • Page 61 consolerc consolerc file erase tftp get consolerc consolerc, MAIN consolerc consolerc consolerc file exec consolerc consolerc consolerc...
  • Page 62 consolerc MAIN consolerc tftp get consolerc Do you want to reset the Switch? admin reboot...
  • Page 63 status show users...
  • Page 64 show system alarms and show system eventlog...
  • Page 65 show stats show signaling summary show signaling summary show signaling summary...
  • Page 66 show signaling summary show signaling cause...
  • Page 67 show signaling stats show lec status show lec config...
  • Page 68 show static_ip status show static_ip status show static_ip client...
  • Page 69 show static_ip server show ppp...
  • Page 70 sync status...
  • Page 71 C aj u n A 5 0 0 ATM S w i t c h C L I C o m ma n d R e f e re n c e S e c t i o n...
  • Page 72 Overview...
  • Page 73 Enter login: root password: A500: show show ? A500:...
  • Page 74 Show Static-IP status [ server ] Show Static-IP server information [ client ] Show Static-IP client information admin static_ip rem_client ? A500: admin static_ip rem_client ? admin static_ip rem_client [admin static_ip rem_client {clientNum}] A500: show system interfaces A500: sh sy i show...
  • Page 76 Are you sure you want to reboot? {verb} {object} {info_type} [target_object] [data] A500: admin link_type Select ATM port (A1.1 - A4.8): admin link_type a1.1...
  • Page 77 A500: admin link_type a1.1 A500: admin link_type Select a configuration for port A1.1: 1) Standard UNI 3.0 2) Standard UNI 3.1 3) IISP Network 4) IISP User 5) Lucent Network Signaling 6) No Signaling 7) Custom... Enter selection: 5 Setting port A1.1 to Lucent Network Signaling...
  • Page 78 198.3.104.162 A500: tftp get directoryname /SWP_IMAGE.IMG Destination [PCMCIA:SWP_IMAGE.IMG]: IP address of TFTP Server [198.3.104.129]: FLASH1: consolerc MAIN: config name SWP_IMAGE.IMG nvram.dat. nvram.dat SWP_IMAGE.IMG MAIN: tftp get FLASH1: SWP_IMAGE.IMG nvram.dat...
  • Page 80 Overview admin Subcommands Command Description...
  • Page 81 Command Description...
  • Page 82 Command Description...
  • Page 83 Purpose admin ack_alrams Syntax admin ack_alarms { all | # } Arguments Example A500: admin ack_alarms all...
  • Page 84 Purpose admin address Syntax admin address { IP address } { subnet mask } Arguments Example A500: admin address Enter IP address[198.3.108.158]: 198.3.108.158 Enter IP mask[255.255.255.0]: 255.255.255.0 New IP address and mask will be used when A500 is rebooted...
  • Page 85 Purpose admin changename Syntax admin changename [ new_name ] Arguments Example A500: admin changename Enter System name (Blank for none):Greyhound...
  • Page 86 Purpose admin changeboot Syntax admin changeboot { bootdevName } { bootfileName } Arguments Example A500: admin changeboot PCMCIA: SWP_IMAGE.IMG Updating NVRAM boot source : [PCMCIA:] [SWP_IMAGE.IMG] NVRAM boot source: Boot device [PCMCIA:] file [SWP_IMAGE.IMG]...
  • Page 87 Purpose admin changeprompt Syntax admin changeprompt { new prompt } Arguments Example A500:admin changeprompt Enter Prompt:Lab1 Lab1:...
  • Page 88 Purpose admin contact Syntax admin contact { contact name } Arguments Example A500: admin contact jsmith...
  • Page 89 Purpose admin downInterface Syntax admin downInterface { Arguments Examples A500:admin downInterface a1.1 Bringing down Board 1, port 1 A500:admin downInterface a1.2 0 Bringing down Board 1, port 2, vpi 0 } [ vpi ] port admin link_type...
  • Page 90 Purpose admin gateway Syntax admin gateway { new_ip_gateway } Arguments Example A500:admin gateway Enter IP gateway[0.0.0.0]: 123.000.103.111 We will clear the A500’s default Gateway IP address Default Gateway will be used when A500 is rebooted. status...
  • Page 91 Purpose admin guestpasswd help show Syntax admin guestpasswd { Arguments Example A500:admin guestpasswd please enter NEW password (maximum of 8 characters)> please enter NEW password, again> new password has been saved new_password...
  • Page 92 Purpose admin inband_address Syntax admin inband_address { IP address } { subnet mask } Arguments Example A500: admin inband_address Enter IP address[0.0.0.0]: 198.3.106.111 Enter IP mask[0.0.0.0]: 255.255.255.0 New IP address and mask will be used when A500 is rebooted...
  • Page 93 Purpose admin interface Syntax admin interface { Arguments Example A500: admin interface a1.1 Select a configuration for port A1.1: 1) SONET 2) SDH Enter selection: 2 port...
  • Page 94 admin link_type Purpose admin link_type Syntax admin link_type { vci] Arguments config } {vpi} {config} [cell rate] [ILMI enable] [max port...
  • Page 95 Select cell rate (10000 - 353207): 10000 Configuring Port A1.8, VPI 0: Auto-configuration, ILMI, Cell Rate 10000, Max VCI 2047 Example 2 A500:admin link_type a1.8 1 2 2046 12345 Configuring Port A1.8, VPI 0: Auto-configuration, ILMI, Cell Rate 112345, Max VCI 2046 (No protocols running) (Auto-configuration) (UNI 3.0 Network)
  • Page 96 Purpose admin location Syntax admin location [ value ] Arguments Example A500: admin location lab3...
  • Page 97 Purpose admin nvram backup Syntax admin nvram backup Arguments Example A500: admin nvram backup ## info : loading into PCMCIA - from 0x33c4cd44, to 0x50000000,size=1892 ## info : loading into PCMCIA - from 0x33c4cd44, to 0x50000000,size=1892 NVRAM CRC 0x88bcf233 ## info : loading into PCMCIA - from 0x33c4cd44, to...
  • Page 98 Arguments Example A500: admin nvram defragment This function will defragment the contents of nvram storage. If the system loses power or is rebooted while the defragment is in progress, the entire contents of nvram may be lost.
  • Page 99 Syntax admin nvram reset Arguments Example A500: admin nvram reset This function will clear the contents of nvram storage. Things such as IP address and port configuration will need to be reinitialized. Do you want to continue? : [n]y...
  • Page 100 Purpose admin nvram restore Syntax admin nvram restore Arguments Example A500: admin nvram restore Restoring NVRAM Entries Successful Creating Entry Type:2 Successful Creating Entry Type:1 Successful Creating Entry Type:8 Successful Creating Entry Type:7 Successful Creating Entry Type:5...
  • Page 101 Purpose admin passwd Syntax admin passwd { Arguments Example A500:admin passwd please enter NEW password (maximum of 8 characters)> please enter NEW password, again> please enter OLD password> new password has been saved new_password current_password...
  • Page 102 Current Setting : Peer Group ID in NVRAM : 47.00.00.00.00.00.00.00.00.00.00.02.00 Use NVRAM Setting for Peer Group ID when rebooted Example 2 A500:admin peergroupid 47000000000000000000000000 New Pnni Peer Group ID is stored in NVRAM and will take effect upon reboot A500:show pnni node...
  • Page 103 Purpose admin pnnilevel Syntax admin pnnilevel { value } Arguments Example A500:admin pnnilevel Enter PNNI LEVEL [96]<values 0-104>:100 New PnniLevel [100] will take effect upon reboot...
  • Page 104 Purpose admin reboot Syntax admin reboot Arguments Example A500: admin reboot Enter 'y' to confirm, 'n' to exit: System Reboot login:...
  • Page 105 Purpose admin readcommunity Syntax admin readcommunity { community name } Arguments Example A500: admin readcommunity Enter system read community:public This parameter will not be used until a subsequent reboot...
  • Page 106 Purpose admin signaling esi add Syntax admin signaling esi add { port } { vpi } { address } Arguments Example A500: admin signaling esi add a1.8 0 11.11.11.11.11.11 added address 47.00.01.11.11.00.04.00.00.01.00.03.01.11.11.11.11.11.11.00 to port a1.8 vpi 0...
  • Page 107 Purpose admin signaling esi remove Syntax admin signaling esi remove { port } { vpi } { address } Arguments Example A500: admin signaling esi remove a1.8 0 11.11.11.11.11.11 removed address 47.00.01.11.11.00.04.00.00.01.00.03.01.11.11.11.11.11.11.00 to port a1.8 vpi 0...
  • Page 108 Purpose admin signaling route add Syntax admin signaling route { port } { vpi } { address } { mask } { default } Arguments Example A500: admin signaling route add...
  • Page 109 Syntax admin signaling route remove { port } { vpi } { address } { mask } { default } Arguments Example 1 A500:admin signaling route remove a1.1 0 390000000000000000c085768 104 Example 2 A500:admin signaling route remove a1.1 0 default...
  • Page 110 Purpose admin static_ip enable_client Syntax admin static_ip enable_client { IP address } { subnet mask } Arguments Example A500: admin static_ip enable_client...
  • Page 111 Purpose admin static_ip enable_server Syntax admin static_ip address { IP address } { subnet mask } Arguments Example A500: admin static_ip enable_server...
  • Page 112 Purpose admin static_ip disable Syntax admin static_ip disable Arguments Example A500: admin static_ip disable...
  • Page 113 Purpose admin static_ip add_client Syntax admin static_ip add_client { ipAddr } { atmAddr } { macAddr } Arguments Example A500: admin static_ip add_client...
  • Page 114 Purpose admin static_ip rem_client Syntax admin static_ip rem_client { clientNum } Arguments Example A500: admin static_ip rem_client Enter client number to remove _...
  • Page 115 Purpose admin static_ip set_server Syntax admin static_ip set_server { atmAddr } Arguments Example A500: admin static_ip set_server...
  • Page 116 Purpose admin switch cdvt Syntax admin switch cdvt { port } { value | default } Arguments Example A500:admin switch cdvt a1.1 250 cdvt for port a1.1 will be 250 microseconds at reboot...
  • Page 117 Syntax admin switch epd enable/disable Arguments Example 1 A500: admin switch epd enable Early Packet Discard is enabled with a queue threshold of 7/8 Example 2 A500: admin switch epd disable Early Packet Discard is disabled admin switch epd enable and admin...
  • Page 118 Purpose admin switch epd threshold Syntax admin switch epd threshold { value (1-7) } Arguments Example A500: admin switch epd threshold 7 Early Packet Discard queue threshold updated to 7/8...
  • Page 119 Purpose admin switch queue capacity Syntax admin switch queue capacity { port } { queue (1-4) } { value } Arguments Example A500: admin switch queue capacity a1.1 3 1000 port A1.1, queue 3: updated, new queue capacity is 767...
  • Page 120 admin switch queue global Purpose admin switch queue global admin switch queue capacity Syntax admin switch queue global { queue (1-4) } { value } Arguments Example show switch queue global...
  • Page 121 Purpose admin switch maxvci Syntax admin switch maxvci { Arguments Example A500:admin switch maxvci a1.1 1790 maxvci for port a1.1 will be 1790 at reboot } { value | default } port...
  • Page 122 Purpose admin telnetflag Syntax admin telnetflag Arguments Example A500: admin telnetflag Telnet sessions are enabled Do you want to change it? : [n]...
  • Page 123 Purpose admin trapcommunity Syntax admin trapcommunity { community name } Arguments Example A500:admin trapcommunity Enter system trap community:support This parameter change will not be used until a subsequent reboot...
  • Page 124 Purpose admin trapdestination Syntax admin trapdestination { IP address } Arguments Example A500:admin trapdestination Enter IP address[]:198.0.000.00 This parameter change will not be used until a subsequent reboot...
  • Page 125 Bringing up Board 1, port 3 Bringing up Board 1, port 3 Example 3 A500:admin ack_alarms all A500:admin upInterface a1.1 0 Bringing up Board 1, port 1, vpi 0 ********** New System Alarms ********** [27] Administrative Status of port brought up...
  • Page 126 Purpose admin time Syntax admin time { dd mm yy hh mm } Arguments Example A500:admin time 12 05 98 17 02 The current system date is Tuesday, May 12, 1998 5:02:00p...
  • Page 127 Purpose admin writecommunity Syntax admin writecommunity { community name } Arguments community name Example A500:admin writecommunity Enter system write community:admin This parameter change will not be used until a subsequent reboot Admin...
  • Page 128 admin zeroerrs Purpose admin zeroerrs show stats error Syntax admin zeroerrs Arguments Example...
  • Page 129 admin zeroEtherstats Purpose admin zeroEtherstats show stats ether Syntax admin zeroEtherstats Arguments Example...
  • Page 130 admin zeroSarstats Purpose admin zeroSarstats show stats errsar Syntax admin zeroSarstats Arguments Example...
  • Page 131 admin zeroSonetstats Purpose admin zeroSonetstats show stats sonetstat Syntax admin zeroSonetstats Arguments Example...
  • Page 132 Overview file Subcommands Command Description...
  • Page 133 Editor Guidelines...
  • Page 134 file cat Purpose file cat Syntax file cat { file_name Arguments Example file_name...
  • Page 135 Purpose file cp Syntax file cp { location:file_name } { location:file_name } Arguments Example A500: file cp FLASH1:SWP_IMAGE.IMG MAIN:west3 Checking for Single Image...Done copy: FLASH1:SWP_IMAGE.IMG to MAIN:west3 Bytes moved:...
  • Page 136 Purpose file cr Syntax file cr { file_name } Arguments Example A500: file cr west2 xos_create_fs : creating west2 erase : erasing west2 consolerc edit...
  • Page 137 file edit Purpose file edit Syntax file edit { file_name } Arguments Instructions file edit cmd: file_name cmd: cmd: cmd: cmd: insert>...
  • Page 138 Purpose file erase Syntax file erase { location:file_name } Arguments Example A500: file erase MAIN:west3 erase : erasing MAIN:west3...
  • Page 139 Purpose file info Syntax file info Arguments Example A500: file info +------------------------------------+ MANUFACTURERS CODE +--------------+---------------------+ |Tuple offset +--------------+---------------------+ | 50000000 | 50000002 | 50000004 | 50000006 +--------------+---------------------+ Value:...
  • Page 140 Purpose file ls Syntax file ls [ -a ] Arguments Example A500: file ls -a File Name --------------------------------------------------------------------- consolerc manifest snmpd.cnf notifyrc acl.pty agt.pty context.pty view.pty wiring script mark FLASH1: SWP_IMAGE.IMG this PCMCIA card is owned by labtech SWP_IMAGE.IMG...
  • Page 141 Output Description Field Description Values...
  • Page 142 file rm Purpose file rm Syntax file rm { file_name | -i index_number } Arguments Example file rm west3 rm: removing west3...
  • Page 144 Overview modify Subcommands Command Description...
  • Page 145 modify add_channel multipoint Purpose modify add_channel multipoint add_channel multipoint Syntax modify add_channel multipoint <input_port> <input_vpi> <input_vci> <output_port> <output_vpi> <output_vci> {class} {incellrate | ppd} Arguments modify...
  • Page 146 Example 1 A500: modify add_channel multipoint input port _ a1.1 input vpi _ 0 input vci _ 100 output port _ a1.2 output vpi _ 0 output vci _ 101 service class _ ubr partial packet discard _ n vci multicast connection added to switch table...
  • Page 147 modify add_channel point-point Purpose modify add_channel point-point Syntax modify add_channel point-point { input_port } { input_vpi } { input_vci { output_port } { output_vpi } { output_vci } { class } { incellrate | ppd } {outcellrate} Arguments...
  • Page 148 Example A500: modify add_channel point-point input port _ a1.1 input vpi _ 0 input vci _ 100 output port _ a1.2 output vpi _ 0 output vci _ 101 service class _ ubr partial packet discard _ y vci connection added to switch table...
  • Page 149 modify add_path multipoint Purpose modify add_path multipoint Syntax modify add_path multipoint { input_port } { input_vpi } { input_vci } { output_port } { output_vpi } { output_vci } {class} {incellrate | ppd} Arguments...
  • Page 150 Example A500: modify add_path multipoint input port _ a1.1 input vpi _ 100 output port _ a1.3 output vpi _ 250 service class _ cbr input peak cell rate _ 100000 vpi multicast connection added to switch table service class CBR Input: Output: port A1.3, vpi 250...
  • Page 151 modify add_path point-point Purpose modify add_path point-point Syntax modify add_path point-point { input_port } { input_vpi } { input_vci } { output_port } { output_vpi } { output_vci } {class} {incellrate | ppd} Arguments...
  • Page 152 Example A500: modify add_path point-point input port _ a1.1 input vpi _ 100 output port _ a2.2 output vpi _ 200 service class _ cbr input peak cell rate _ 100000 output peak cell rate _ 100000 vpi connection added to switch table...
  • Page 153 Purpose Syntax modify atmprefix { new_prefix } Arguments Example A500: modify atmprefix 390000000000000000C60368A0 New ATM prefix will be used when platform is rebooted modify atmprefix...
  • Page 154 Purpose modify console autologout Syntax modify console autologout { on | off } Arguments Example A500: modify console autologout on...
  • Page 155 Purpose modify console timeout Syntax modify console timeout { value } Arguments Example A500: modify console timeout 5...
  • Page 156 { input_port } { input_vpi } { input_vci } { output_port } { output_vpi } { output_vci } Arguments Example 1 A500: modify rem_channel input port _ a1.1 input vpi _ 0 input vci _ 100 output port _ a1.2...
  • Page 157 Example 2 A500: modify rem_channel input port _ a1.1 input vpi _ 0 input vci _ 100 output port _ a1.3 output vpi _ 0 output vci _ 101 vci multicast connection removed from switch table Input: Output: port A1.3, vpi port A1.1, vpi...
  • Page 158 Syntax modify rem_channel { input_port } { input_vpi } { output_port } { output_vpi } Arguments Example A500: modify rem_path input port _ a1.1 input vpi _ 100 output port _ a1.3 output vpi _ 250 vpi multicast connection removed from switch table Input: Output: port A1.3, vpi 250...
  • Page 160 Overview Subcommands Command Description...
  • Page 161 Command Description...
  • Page 162 Purpose ppp display Syntax ppp display Arguments Example A500:ppp display PPP is enabled PPP down! PPP Local IP Address ---------------- address 192.168.55.1 mask 255.255.255.0 Dial Out Configuration ---------------- Dial Out virtual PPP channel is not being used DialOut User Name:...
  • Page 163 Purpose ppp localPppHost Syntax ppp localPppHost { hostname } Arguments Example A500:ppp localPppHost...
  • Page 164 Purpose ppp modem modemDialStrIN Syntax ppp modem modemDialStrIN { value } Arguments Example A500:ppp modem modemDialStrIN...
  • Page 165 Purpose ppp modem modemDialStrOUT Syntax ppp modem modemDialStrOUT { value } Arguments Example A500:ppp modem modemDialStrOUT...
  • Page 166 Purpose ppp modem modemHangupStr Syntax ppp modem modemHangupStr { value } Arguments Example A500:ppp modem modemHangupStr...
  • Page 167 Purpose ppp modem modemSetupStr Syntax ppp modem modemSetupStr Arguments Example A500:ppp modem modemSetupStr...
  • Page 168 Purpose ppp setCHAP Syntax ppp setCHAP { hostname | secret } Arguments Example A500:ppp setCHAP dialup server name...
  • Page 169 Syntax ppp setdialin authentIn { PAP | CHAP } Arguments Example 1 A500:ppp setdialin authentIn PAP Do you want to use Password Authentication Protocol (PAP):[n] Example 2 A500:ppp setdialin authentIn CHAP Do you want to use Challenge Handshake Authentication Protocol...
  • Page 170 Purpose ppp setdialin peerIPIn Syntax ppp setdialin peerIPIn { IP address } Arguments Example A500:ppp setdialin peerIPIn...
  • Page 171 Syntax ppp setdialout authentOut { PAP | CHAP } Arguments Example 1 A500:ppp setdialout authentOut PAP Do you want to use Password Authentication Protocol (PAP):[n] Example 2 A500:ppp setdialout authentOut CHAP Do you want to use Challenge Handshake Authentication Protocol...
  • Page 172 Purpose ppp setdialout delay_timer Syntax ppp setdialout delay_timer { hours | minutes } Arguments Example A500:ppp setdialout delay_timer Current delay timer value: 0 hours and 0 minutes Enter hours:0 Enter minutes:5...
  • Page 173 Purpose ppp setdialout peerIPOut Syntax ppp setdialout peerIPOut { IP address } Arguments Example A500:ppp setdialout peerIPOut...
  • Page 174 Purpose ppp setdialout pppModeOut Syntax ppp setdialout pppModeOut { 1 | 2 } Arguments Example 1 A500:ppp setdialout pppModeOut Select mode for dial out port: 1)PPP mode Active 2)Virtual dial out port not used Enter selection:...
  • Page 175 Purpose ppp setdialout namePassOut Syntax ppp setdialout namePassOut { name | password } Arguments Example A500:ppp setdialout namePassOut...
  • Page 176 Purpose ppp setdialout teleNum Syntax ppp setdialout teleNum { number } Arguments Example A500:ppp setdialout teleNum DialOut Telephone Number: Do you want to change it?:[n]y Enter 20 character or less telephone number:18881234567...
  • Page 177 Syntax ppp setPAP { username | password | message } Arguments Example A500: ppp setPAP password index 1 - user name:my_name password:******* message:LOGIN OK password index 2 - empty table entry Enter desired index (default is no changes):1...
  • Page 178 Current local ppp address is:192.000.00.0 Do you want to change the local ppp IP address?:[n]y Enter IP address in dotted decimal form:192.111.11.1 Please reboot A500 or cycle modem power when finished editing ppp configuration Current local ppp IP subnet mask is:255.000.000.0 Do you want to change the local ppp IP subnet mask?:[n]y Enter subnet mask in dotted decimal form:255.111.111.1...
  • Page 180 Overview show Subcommands Command Description...
  • Page 181 Command Description...
  • Page 182 Command Description...
  • Page 183 Command Description...
  • Page 184 Purpose show ethernet showIB Syntax show ethernet showIB Arguments Example A500: show ethernet showIB Initialization Block @ 0x32341d20: mode: 0080 padr[15:00]: 2000 padr[31:16]: 14B6 padr[47:32]: 00DE ladrf[15:00]: 0000 ladrf[31:16]: 0000 ladrf[47:32]: 0000 ladrf[63:48]: 0000...
  • Page 185 Syntax show ethernet showrings Arguments Example A500: show ethernet showrings Rx Descriptor Ring: Desc 00 @ 0x32306ab0 = 32CF56E0 FFFFF800 00000000 00000000 Desc 01 @ 0x32306ac0 = 32CF5EE0 FFFFF800 00000000 00000000 Desc 02 @ 0x32306ad0 = 32CF66E0 FFFFF800 00000000 00000000...
  • Page 186 Syntax show ethernet showregs Arguments Example A500: show ethernet showregs CSR0: FFFF0173, CSR3: FFFF0B00, CSR4: FFFF0115, CSR15: FFFFFFFF, CSR80: FFFFFFFF BCR0: FFFF0005, BCR1: FFFF0005, BCR2: FFFF0080, BCR3: FFFF0000, BCR4: FFFF00C0 BCR5: FFFF0084, BCR6: FFFF8088, BCR7: FFFF0090, BCR8: FFFF0000...
  • Page 187 Purpose show lec config Syntax show lec config Arguments Example A500:show lec config LEC Configuration ================= Initialization Method:Use well known LECS address. Manual LES ATM Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 ELAN Name:...
  • Page 188 Purpose show lec status Syntax show lec status Arguments Example A500:show lec status LEC Status ========== LEC ID:0 LECS Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 LES Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 State:Initial ELAN Name:...
  • Page 189 Purpose show link_type Syntax show link_type { port } Arguments Example A500:show link_type a2.4 Port VPI Protocol(s) ---- --- ------------------------ ------- ---- A2.4 0 Auto-configuration, ILMI 0353207 65535 Rate...
  • Page 190 Purpose show pnni hmap Syntax show pnni hmap Arguments Example A500:show pnni hmap ***** PNNI HMAP INFORMATION ***** ====================================================================== ======== 60a0390000000000000000c0a84b230020b6171b0000 390000000000000000c0a84b230020b6171b0000 NODE ID ATM Address...
  • Page 191 Purpose show pnni neighbor Syntax show pnni neighbor Arguments Example A500:show pnni neighbor ***** PNNI NEIGHBOR INFORMATION ***** Port ID ====================================================================== Link State Remode Node ID...
  • Page 192 Purpose show pnni base Syntax show pnni base Arguments Example A500:show pnni base PNNI Base Group keepgoing = 0x1 pnniHighestVersion pnniLowestVersion pnniDtlCountOriginator pnniDtlCountBorder pnniCrankbackCountOriginator pnniAltRouteCountBorder pnniAltRouteCountOriginator pnniAltRouteCountBorder pnniRouteFailCountOriginator pnniRouteFailCountBorder pnniRouteFailUnreachableOriginator pnniRouteFailUnreachableBorder 4000 4000...
  • Page 193 Purpose show pnni node mib Syntax show pnni node mib Arguments Example A500:show pnni node mib ***** PNNI NODE INFORMATION ***** Level Node ID (HEX) Peer Group ID (HEX) : 60390000000000000000c0a84b00 ATM Address (HEX) : 96...
  • Page 194 Purpose show pnni mib addmap Syntax show pnni mib addmap Arguments Example A500:show pnni mib addmap PNNI Map Address Table keepgoing = 0x1 pnniNodeIndex pnniMapAddrAdvertisingNodeId 60a0390000000000000000c0a84b230020b6171b0000 pnniMapAddrAdvertisedPortId pnniMapAddrIndex pnniMapAddrPrefixLength keepgoing = 0x1 pnniNodeIndex pnniMapAddrAdvertisingNodeId 60a0390000000000000000c0a84b240020b6171a0000 pnniMapAddrAdvertisedPortId...
  • Page 195 Purpose show pnni mib pgl Syntax show pnni mib pgl Arguments Example 1 A500:show pnni mib pgl PNNI PGL Election Table keepgoing = 0x1 pnniNodeIndex pnniNodePglLeadershipPriority pnniNodeCfgParentNodeIndex pnniNodePglInitTime pnniNodePglOverrideDelay pnniNodePglReelectTime pnniNodePglState pnniNodePreferredPgl pnniNodePeerGroupLeader pnniNodePglTimeStamp pnniNodeActiveParentNodeId 00000000000000000000000000000000000000000000...
  • Page 196 Purpose show pnni mib timer Syntax show pnni mib timer Arguments Example A500:show pnni mib timer PNNI Initial Timer Table keepgoing = 0x1 pnniNodeIndex pnniNodePtseHolddown pnniNodeHelloHolddown pnniNodeHelloInterval pnniNodeHelloInactivityFactor pnniNodeHlinkInact pnniNodePtseRefreshInterval pnniNodePtseLifetimeFactor pnniNodeRxmtInterval pnniNodePeerDelayedAckInterval pnniNodeAvcrPm pnniNodeAvcrMt pnniNodeCdvPm...
  • Page 197 Purpose show pnni mib svcct Syntax show pnni mib svcct Arguments Example A500:show pnni mib svcct PNNI SVCC Table keepgoing = 0x1 pnniNodeIndex pnniNodeSvccInitTime pnniNodeSvccRetryTime pnniNodeSvccCallingIntegrityTime pnniNodeSvccCalledIntegrityTime pnniNodeSvccTrafficDescriptorIndex keepgoing = 0x6...
  • Page 198 Purpose show pnni mib scope Syntax show pnni mib scope Arguments Example A500:show pnni mib scope PNNI Scope Mapping Table keepgoing = 0x1 pnniNodeIndex pnniScopeLocalNetwork pnniScopeLocalNetworkPlusOne pnniScopeLocalNetworkPlusTwo pnniScopeSiteMinusOne pnniScopeIntraSite pnniScopeSitePlusOne pnniScopeOrganizationMinusOne pnniNodeIndex pnniScopeOrganizationPlusOne pnniScopeCommunityMinusOne pnniScopeIntraCommunity pnniScopeCommunityPlusOne...
  • Page 199 Purpose show pnni mib interface Syntax show pnni mib interface Arguments Example A500:show pnni mib interface PNNI Interface Table keepgoing = 0x1 pnniIfNodeIndex pnniNodeIndex pnniIfPortId pnniIfAggrToken pnniIfVPCapability pnniIfAdmWeightCbr pnniIfAdmWeightRtVbr pnniIfAdmWeightNrtVbr pnniIfAdmWeightAbr pnniIfAdmWeightUbr pnniIfRccServiceCategory pnniIfRccTrafficDescrIndex keepgoing = 0x6...
  • Page 200 Purpose show pnni mib link Syntax show pnni mib link Arguments Example A500:show pnni mib link PNNI Link Table keepgoing = 0x1 pnniNodeIndex pnniLinkPortId pnniLinkpnniDisplay pnniLinkVersion pnniLinkHelloState pnniLinkRemoteNodeId pnniLinkRemotePortId pnniLinkDerivedAggrToken pnniLinkUpnodeId pnniLinkUpnodeAtmAddress pnniLinkCommonPeerGroupId pnniLinkIfIndex pnniLinkSvccRccIndex pnniLinkRcvHellos...
  • Page 201 Purpose show pnni mib map Syntax show pnni mib map Arguments Example A500:show pnni mib map pnniMapOriginatingPortId pnniMapIndex pnniMappnniDisplay pnniMapPeerGroupId pnniMapAggrToken pnniMapRemoteNodeId pnniMapRemotePortId pnniMapVPCapability pnniMapPtseId pnniMapMetricsTag keepgoing = 0x1 pnniNodeIndex pnniMapOriginatingNodeId pnniMapOriginatingPortId pnniMapIndex pnniMappnniDisplay pnniMapPeerGroupId pnniMapAggrToken...
  • Page 202 Purpose show pnni mib metrics Syntax show pnni mib metrics Arguments Example A500:show pnni mib metrics pnniMetrics4 pnniMetrics5 pnniMetrics6 pnniMetrics7 pnniMetrics8 pnniMetricsRowStatus keepgoing = 0x1 pnniNodeIndex pnniMetricsTag pnniMetricsDirection pnniMetricsIndex pnniMetricsClasses pnniMetricsGcacClp pnniMetricsAdminWeight pnniMetrics1 pnniMetrics2 pnniMetrics3 pnniMetrics4...
  • Page 203 Purpose show pnni mib nmap Syntax show pnni mib nmap Arguments Example A500:show pnni mib nmap pnniMapNodeIAmLeader pnniMapNodeLeadershipPriority pnniMapNodePreferredPgl pnniMapNodeParentNodeId pnniMapNodeParentAtmAddress 00000000000000000000000000000000000000000000 pnniMapNodeParentPeerGroupId pnniMapNodeParentPglNodeId 00000000000000000000000000000000000000000000 keepgoing = 0x1 pnniNodeIndex pnniMapNodeId pnniMapNodePeerGroupId pnniMapNodeAtmAddress pnniMapNodeRestrictedTransit pnniMapNodeComplexRep pnniMapNodeRestrictedBranching pnniMapNodeDatabaseOverload...
  • Page 204 Purpose show pnni mib npeert Syntax show pnni mib npeert Arguments Example A500:show pnni mib npeert PNNI Neighboring Peer Table keepgoing = 0x1 pnniNodeIndex pnniNbrPeerRemoteNodeId pnniNbrPeerState pnniNbrPeerSvccRccIndex pnniNbrPeerPortCount pnniNbrPeerRcvDbSums pnniNbrPeerXmtDbSums pnniNbrPeerRcvPtsps pnniNbrPeerXmtPtsps pnniNbrPeerRcvPtseReqs pnniNbrPeerXmtPtseReqs pnniNbrPeerRcvPtseAcks pnniNbrPeerXmtPtseAcks...
  • Page 205 Purpose show pnni mib npeerport Syntax show pnni mib npeerport Arguments Example A500:show pnni mib npeerport PNNI Neighboring Peer Port Table keepgoing = 0x1 pnniNodeIndex pnniLinkRemoteNodeId pnniNbrPeerPortId pnniNbrPeerPortFloodStatus keepgoing = 0x6 60a0390000000000000000c0a84b230020b6171b0000 17825792...
  • Page 206 Purpose show pnni mib ptse Syntax show pnni mib ptse Arguments Example A500:show pnni mib ptse pnniNodeIndex pnniPtseOriginatingNodeId 60a0390000000000000000c0a84b240020b6171a0000 pnniPtseId pnniPtsepnniDisplay pnniPtseSequenceNum pnniPtseChecksum pnniPtseLifeTime keepgoing = 0x1 pnniNodeIndex pnniPtseOriginatingNodeId 60a0390000000000000000c0a84b240020b6171a0000 pnniPtseId pnniPtsepnniDisplay pnniPtseSequenceNum pnniPtseChecksum pnniPtseLifeTime keepgoing = 0x1...
  • Page 207 Purpose show pnni mib rnode Syntax show pnni mib rnode Arguments Example A500:show pnni mib rnode PNNI Route Node Table keepgoing = 0x6...
  • Page 208 Purpose show pnni mib raddr Syntax show pnni mib raddr Arguments Example A500:show pnni mib raddr pnniRouteAddrPtseId pnniRouteAddrOriginateAdvertisement pnniRouteAddrOperStatus pnniRouteAddrTimeStamp pnniRouteAddrRowStatus keepgoing = 0x1 pnniNodeIndex pnniRouteAddrAddress pnniRouteAddrPrefixLength pnniRouteAddrIndex pnniRouteAddrIfIndex pnniRouteAddrAdvertisingNodeId 60a0390000000000000000c0a84b240020b6171a0000 pnniRouteAddrAdvertisedPortId pnniRouteAddrpnniDisplay pnniRouteAddrProto pnniRouteAddrPnniScope pnniRouteAddrVPCapability...
  • Page 209 Purpose show pnni mib rbase Syntax show pnni mib rbase Arguments Example A500:show pnni mib rbase PNNI Route Base Table keepgoing = 0x6...
  • Page 210 Purpose show pnni mib rdtl Syntax show pnni mib rdtl Arguments Example A500:show pnni mib rdtl PNNI Route Node Table keepgoing = 0x6...
  • Page 211 Purpose show pnni mib rtns Syntax show pnni mib rtns Arguments Example A500:show pnni mib rtns PNNI Route TNS Table keepgoing = 0x6...
  • Page 212 Purpose show pnni mib summary Syntax show pnni mib summary Arguments Example A500:show pnni mib summary PNNI Summary Advertising Table keepgoing = 0x1 pnniNodeIndex pnniSummaryAddress pnniSummaryPrefixLength pnniSummarypnniDisplay pnniSummarySuppress pnniSummaryState pnniSummaryRowStatus keepgoing = 0x6 390000000000000000c0a84b24000000000000...
  • Page 213 Purpose show pnni mib summaddress Syntax show pnni mib summaddress Arguments Example A500:show pnni mib summaddress PNNI SUMMARY ADDRESS TABLE keepgoing = 0x1 pnniNodeIndex pnniSummaryAddress pnniSummaryPrefixLength pnniSummarypnniDisplay pnniSummarySuppress pnniSummaryState pnniSummaryRowStatus keepgoing = 0x6 390000000000000000c0a84b24000000000000...
  • Page 214 Purpose show pnni mib svccrcc Syntax show pnni mib svccrcc Arguments Example A500:show pnni mib svccrcc PNNI SVCC RCC Table keepgoing = 0x6...
  • Page 215 Purpose show pnni mib tnsmap Syntax show pnni mib tnsmap Arguments Example A500:show pnni mib tnsmap PNNI Map TNS Table keepgoing = 0x6...
  • Page 216 Purpose show pnni node Syntax show pnni node Arguments Example A500:show pnni node ***** PNNI NODE INFORMATION ***** Level Node ID (HEX) Peer Group ID (HEX) : 60390000000000000000c0a84b00 ATM Address (HEX) : 96 : 60a0390000000000000000c0a84b230020b6171b0000 : 390000000000000000c0a84b230020b6171b0000...
  • Page 217 Purpose show pnni rouadd Syntax show pnni rouadd Arguments Example A500:show pnni rouadd ***** PNNI ROUTE ADDRESS INFORMATION ***** ********* ADDRESSES LEARNED FROM LOCAL AND MANAGEMENT PROTOCOL *********** Address ============================================================================ 39000000000000000001010105000000000000 39000000000000000001010106000000000000 390000000000000000c0a84b230020b6171b00 ************ ADDRESSES LEARNED FROM PNNI PROTOCOL ***************...
  • Page 218 Purpose show ppp Syntax show ppp Arguments Example A500:show ppp PPP is enabled PPP down! PPP Local IP Address ---------------- address 192.168.55.1 mask 255.255.255.0 Dial Out Configuration ---------------- Dial Out virtual PPP channel is not being used DialOut User Name:...
  • Page 219 Purpose show signaling cause Syntax show signaling cause { cause # } Arguments Example 1 A500:show signaling cause 2 Cause 2: No route to specified transit network Example 2 A500:show signaling cause Cause ----- --------------------------------------------------- Unallocated (unassigned) number...
  • Page 220 No VPCI/VCI available Resource unavailable, unspecified Quality of Service unavailable User cell rate not available Call cleared due to change in PGL Bearer capability not authorized Bearer capability not presently available Service or option not available, unspecified Bearer capability not implemented Unsupported combination of traffic parameters Invalid call reference value Identified channel does not exist...
  • Page 221 Purpose show signaling esi Syntax show signaling esi Arguments Example A500:show signaling esi Number of ESI's Allowed: 32 Current number of ESI's: 0 port ---------- ---- ----...
  • Page 222 Purpose show signaling routes Syntax show signaling routes Arguments Example A500:show signaling routes Number of Local Static Routes Allowed: 32 Number of Local Static Routes Allowed: 32 Current number of Local Static Routes: 2 Port Address ---- ----------------------------------------------------------- A?.?
  • Page 223 Purpose show signaling stats Syntax show signaling stats { vpi } { port } Arguments Example A500:show signaling stats 35 a1.1 Signaling Statistics Port A1.1 if_index = 0x1010000 sscop con events = 3 sscop errored pdus = 1 received setup attempts = 0...
  • Page 224 SSG STATISTICS reset ssg stats = 0 parse statistics no of messages received with invalid protocol discriminator = 0 no of messages received with call reference length errorsi = 0 SETUP messages received with call reference flag incorrectly set to 1=0 no of invalid call reference = 0 no of unrecognized messages received with pass along bit set = 0 no of unrecognized messages received and discarded = 0...
  • Page 225 Error Recovery PDUs - num trans = 0 - num rcvd = 0 - num retrans rcvd = 0 - num retrans trans = 0 - num acks trans = 0 - num acks rcvd = 0 - num rej rcvd = 0 - num rej trans = 0 End PDUs - num trans = 1...
  • Page 226 Syntax show signaling summary [ port ] [ vpi ] Arguments Examples A500:show signaling summary Link Phy Admin ILMI Port VPI Config State State State ---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- A1.1 0...
  • Page 227 ---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- ---- - A1.1 0 Auto Down A1.1 100 UNI4.0 Down A500:show signaling summary a1.1 100 Link Admin Port VPI Config State State ---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- ---- - A1.1 100 UNI4.0 Down...
  • Page 228 ILMI states: ------------ DOWN -> ilmi state machine is not running, port/vpi is admin down INITIALIZIN -> ilmi process is being initialized INITIALIZED -> ilmi process has completed initialization CONNECTED -> ilmi process has connected to a remote peer CONFIGURED ->...
  • Page 229 Purpose show static_ip client Syntax show static_ip client Arguments Example A500:show static_ip client Client address: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00...
  • Page 230 Purpose show static_ip server Syntax show static_ip server Arguments Example A500:show static_ip server Server address: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00...
  • Page 231 Purpose show static_ip status Syntax show static_ip status Arguments Example A500:show static_ip status Static-IP Status ================ Current Status: Current Mode: Nvram Status: Nvram Mode: DISABLED CLIENT DISABLED CLIENT...
  • Page 232 Purpose show stats cellstat Syntax show stats cellstat Arguments Example A500: show stats cellstat ------------------------------------ Current Switch Cell Statistics ------------------------------------ Priority 1 cells = Priority 2 cells = Priority 3 cells = Priority 4 cells = total cells...
  • Page 233 Purpose show stats errether Syntax show stats errether Arguments Example A500: show stats errether T_DSCRDS T_COLL -------- ------ R_DSCRDS R_MISSED -------- -------- Output Description Field T_CAR T_RETRY T_BABBLE ----- ------- -------- R_COLL R_RUNT ------ ------ Description Values...
  • Page 234 Purpose show stats errsar Syntax show stats errsar Arguments Example A500: show stats errsar Port HW Err ---- -------- A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A2.1 A2.2 A2.3 A2.4 A2.5 A2.6 A3.1 A3.2 A3.3 A3.4 A3.5 A3.6 A4.1...
  • Page 235 Output Description Field Description...
  • Page 236 Purpose show stats ether Syntax show stats ether Arguments Example A500: show stats ether ETHERNET PORT In Octets In Unicast Frames ---------- ----------------- Out Octets Out Unicast Frames ---------- ----------------- Output Description Field In NUnicast Frames ------------------...
  • Page 237 Purpose show stats memstat Syntax show stats memstat Arguments Example A500: show stats memstat LUT Memory Management Statistics -------------------------------- vc slots vp slots free slots ITT Memory Management Statistics -------------------------------- free slots in-use slots OPT Memory Management Statistics...
  • Page 238 OTT Memory Management Statistics -------------------------------- point-point slots = multi-point slots = free slots Output Description Field 65535 Description Values...
  • Page 239 Syntax show stats queuestat { port | all } Arguments Example A500: show stats queuestat a1.1 Port A1.1 Queue Statistics -------------------------------- priority 1: input enabled, output enabled, cell count = 0 priority 2: input enabled, output enabled, cell count = 0...
  • Page 240 Purpose show stats sar Syntax show stats sar Arguments Example A500: show stats sar Port In Octets ---- --------- Output Description Field Out Octets In PDUs Out PDUs ---------- --------- ---------- 1127651 25904 Description...
  • Page 241 Purpose show stats portstat Syntax show stats portstat { port } Arguments Example A500: show stats portstat <port#> _ a1.2 Sonet per Port Statistics --------------------------------- Receive Cell Count: Transmit Cell Count: Section Level Bit Err: Line Bit Err:...
  • Page 242 Output Description Field Description Values...
  • Page 243 Purpose show stats swstat Syntax show stats swstat Arguments Example A500: show stats swstat --------------------------------------- Cumulative Switch Cell Statistics --------------------------------------- discarded cells invalid cells Output Description Field Description Values...
  • Page 244 Purpose show switch busy_vcis Syntax show switch busy_vcis { port } { vpi } Arguments Example A500: show switch busy_vcis a1.2 0 Busy vcis for port A1.2, VPI --------------------------------...
  • Page 245 Purpose show switch cdvt Syntax show switch cdvt { port | all } Arguments Example A500:show switch cdvt a1.1 A1.1 cell delay variation tolerance values ------------------------------------------ current cdvt for port reboot cdvt for port 250 microseconds 250 microseconds...
  • Page 246 Purpose show switch chipversions Syntax show switch chipversions Arguments Example A500: show switch chipversions white chip version = 2 grey chip version = 2 pif chip version numbers: port A1.1...not available port A1.2...not available port A1.3...not available port A1.4...not available...
  • Page 247 Purpose show switch circuittable Syntax show switch circuittable [ all | port # ] Arguments Example A500: show switch circuittable ___________________________________________________________________ Input |port vpi vci| port vpi |_____________|______________|______________________________________ A1.1 A1.1 A1.3 A1.5 100 A1.6 A1.8 Output Connection vci| type class A1.8...
  • Page 248 Output Description Field Description Values...
  • Page 249 Purpose show switch epd Syntax show switch epd Arguments Example 1 A500: show switch epd Early Packet Discard is enabled with a queue threshold of 7/8 Example 2 A500:sh switch epd Early Packet Discard is disabled...
  • Page 250 Purpose show switch free_vcis Syntax show switch free_vcis { port } { vpi } Arguments Example A500: show switch free_vcis port _ a1.2 VPI _ 0 Free vcis for port A1.2, VPI -------------------------------- 102, 103, 104, 112,...
  • Page 251 Purpose show switch maxvci Syntax show switch maxvci [ port ] Arguments Example A500:show switch maxvci a1.1 A1.1 maximum vci values ----------------------- current maximum vci for port reboot maximum vci for port admin switch maxvci 2015 1790...
  • Page 252 Purpose show switch queue capacities Syntax show switch queue capacities { port | all } Arguments Example A500: show switch queue capacities a1.1 Queue Cell Capacities For Port A1.1 ----------------------------------- priority 1: priority 2: priority 3: priority 4:...
  • Page 253 Purpose show switch queue global Syntax show switch queue global Arguments Example A500: show switch queue global Global Queue Cell Capacities For Switch --------------------------------------- global queue 1: global queue 2: 65535 cells global queue 3: global queue 4: 49152 cells...
  • Page 254 Purpose show system alarms Syntax show system alarms Arguments Example A500: show system alarms Current System Alarms --------------------- [1] Failed to fetch configuration files [4] Power Supply failure [28] Board Removed show system alarms...
  • Page 255 Purpose show system bootSource Syntax show system bootSource Arguments Example A500: show system bootSource NVRAM boot source: Boot device [PCMCIA:] file [SWP_IMAGE.IMG] offset [0x0]...
  • Page 256 Purpose show system chassis Syntax show system chassis Arguments Example A500:show system chassis _________________________________________________ __________________________________________________ Power supply 1... Not installed Power supply 2... OK AC Power 2... OK DC Power 2... OK PHY Slot 1 ... Present PHY Slot 2 ...
  • Page 257 Output Description Field Description Values...
  • Page 258 Purpose show system community Syntax show system community Arguments Example A500: show system community Read Community: techpub Write Community: sysadmin Trap Community: engineer...
  • Page 259: Show System Configuration

    Purpose show system configuration Syntax show system configuration Arguments Example A500: show system configuration __________________________________________________ __________________________________________________ A500 name IP address IP mask A500 address A500 ATM address 39.0000.000000000000C60368B0.0020B616E400.00 Console timeout in minutes Cajun A500 Database -- A500 -- 198.3.104.176...
  • Page 260 Syntax show system crash_info { all | last | num | Arguments Example A500: show system crash_info all Crash occured because of NMI Running A500 software version: UNOFFICIAL Crash occured on 3/19/99 at 17:29:18 SWP: g: 0x30292180 0x31EF293C 0x00000000 0x00000064...
  • Page 261 Purpose show system eventlog Syntax show system eventlog Arguments Example A500: show system eventlog System up time ---------------- 0:00:54.78 Event ----------------------------------------- Succeeded fetching configuration files...
  • Page 262 Purpose show system interfaces Syntax show system interfaces Arguments Example A500: show system interfaces Device Oper Status _________________________________________________________________ Self Self Output Description Field Admin State Type Status present PROPVIRTUAL present Description Values...
  • Page 263 Purpose show system que Syntax show system que Arguments Example A500: show system que Port ------------------------------------ ETHER 0/64 0/64 Output Description Field TxFQ RxFQ 64/64 0/64 64/64 64/64 0/64 64/64 Description Values...
  • Page 264 Purpose show system seeprom bp_base Syntax show system seemprom bp_base Arguments Example A500:show system seeprom bp_base A500 MAC Address: Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 0:20:b6:17:1a:0 10010062...
  • Page 265 Purpose show system seeprom bp_card Syntax show system seemprom bp_card Arguments Example A500:show system seeprom bp_card Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010011 ÿ ÿÿ ÿÿ ÿÿ...
  • Page 266 Purpose show system seeprom bp_chassis Syntax show system seemprom bp_chassis Arguments Example A500:show system seeprom bp_chassis Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010033 ÿ ÿÿ ÿÿ ÿÿ...
  • Page 267 Purpose show system seeprom phy# Syntax show system seemprom phy# Arguments Example A500: show system seeprom phy2 Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010160 ÿÿ ÿÿÿÿÿ ÿÿÿÿ...
  • Page 268 Purpose show system seeprom swf Syntax show system seemprom swf Arguments Example A500:show system seeprom swf Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number:...
  • Page 269 Purpose show system seeprom swp Syntax show system seemprom swp Arguments Example A500: show system seeprom swp A500 MAC Address: Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 0:20:b6:14:de:0 ÿÿÿÿÿÿÿÿ...
  • Page 270 Purpose show system seeprom swp Syntax show system seemprom sync Arguments Example A500:show system seeprom sync Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010121 Stratum 3/4 ÿ ÿÿ...
  • Page 271 Purpose show system stack Syntax show system stack Arguments Example A500:show system stack IfIndex ____________________________________________________________ Higher Lower Status...
  • Page 272: Show Time

    Purpose show time Syntax show time Arguments Example A500:show time The current system date is Tuesday, April 6, 1999 2:35:23p...
  • Page 273 Purpose show trapinfo Syntax show trapinfo Arguments Example A500:show trapinfo Trap Community public Trap Destination IP address 192.168.75.22...
  • Page 274: Show Users

    Purpose show users Syntax show users Arguments Example A500:show users Device Login Name ------ ---------- Type From ------ ----------------- root Telnet nnn.n.nnn.nn root Direct...
  • Page 275: Show Version

    Purpose show version Syntax show version Arguments Example A500: show version IMAGE VERSIONS LoadedImage ----------- --------------- -------- PCMCIAImage ----------- --------------- -------- PCMCIA:SWP FLASH1Image ----------- --------------- -------- FLASH1:SWP Version Date 3.00 01/04/99 Version Date 3.00 01/04/99 Version Date ACE_100.15...
  • Page 276 Overview sync Subcommands Command diag dext diag dline diag dprov diag dstats enable/disable mode holdover mode lock setsync status Description...
  • Page 277 Purpose sync diag dext Syntax sync diag dext Arguments Example A500:sync diag dext External Reference #1 Provisioning and Status FRAME: [0x 0x E12_DCA: [0x00d7] 0x00 E12_SQ: [0x 0x DELTA: [0x0105] 0x27 STATUS: [0x050a] 0x27 MASK: [0x0805] 0x27...
  • Page 278 Purpose sync diag dline Syntax sync diag dline Arguments Example A500:sync diag dline Line Reference Provisioning and Status LOREF_D: [0x010c] 0x00 LOREF_S: [0x0524] 0xdf LOREF_DM: [0x080c] 0x00 Line Reference 1: Line Reference 2:...
  • Page 279 Purpose sync diag dprov Syntax sync diag dprov Arguments Example A500:sync diag dprov TG Registers - Provisioning PREDIV: [0x00aa] 0x0304 MSSEL: [0x00f1] 0x01 REFSELIN: [0x00a8] 0x02 DCA: [0x00a9] 0x1f MODE: [0x00bc] 0x02 SETGCTL: [0x00be] 0x06 DMSSM MSS[0x 0]...
  • Page 280 Purpose sync diag dstats Syntax sync diag dstats Arguments Example A500:sync diag dstats TG Registers - Status TG addr: [81000000] Status: [0x0000] 0x0003 ID/Version: [0x0002] 0x0010 SAR: [0x0008] 0xaa55 CD1: [0x0020] 0x0000 CD2: [0x0022] 0x0000 CE1: [0x0040] 0x0000...
  • Page 281 Purpose sync enable/disable Syntax sync enable sync disable Arguments Example 1 A500:sync enable This Function will enable the sync card and reboot the system Do you want to continue? : [n]y Enabling sync card ... System Reboot ... Example 2...
  • Page 282 Syntax sync mode holdover sync mode lock Arguments Example 1 A500:sync mode holdover This Function commands the sync card to go to holdover mode Do you want to continue? : [n]y Successful Example 2 A500:sync mode lock This Function commands the sync card to go to locked mode...
  • Page 283 sync setsync Purpose sync setsync Syntax sync setsync Arguments...
  • Page 284 Example A500:sync setsync Sync Card Configuration Timing Reference Priorities --------------------------- - priority range <0 thru 4> (4 highest, 1 lowest, 0 disable) Enter the Priorities: Primary OC-N [4]: Secondary OC-N [3]: Primary Secondary Ext External Reference Type ----------------------- - for DS1 enter 1, for E1 enter 2...
  • Page 285 Purpose sync status Syntax sync status Arguments Example A500:sync status Sync Card Status ---------------- Sync Card State: ... Enabled Sync Card: Sync Mode:... Locked Current Reference:... Primary Reference --------- Primary OC-N: Secondary OC-N: Primary Ext : Secondary Ext : Wait to Restore Time: ...
  • Page 286 Overview tftp Subcommands Command Description...
  • Page 287: Tftp Get

    Purpose tftp get Syntax tftp get { file_name Arguments Example A500: tftp get SWP_IMAGE.IMG PCMCIA:SWP_IMAGE.IMG 192.3.11.129 Attempting to TFTP file from host 192.3.11.129 Source: SWP_IMAGE.IMG Destination: PCMCIA:SWP_IMAGE.IMG Starting Server located. Bytes received: Done. File 'SWP_IMAGE.IMG' - 1062811 bytes - received.
  • Page 288 Purpose tftp setserver Syntax tftp setserver { Arguments Example A500:tftp setserver TFTP Server IP address _ 198.3.111.246 The new address will be used on the next TFTP request. server_IP_address...
  • Page 289: Tftp Status

    Purpose tftp status Syntax tftp status Arguments Example 1 A500:tftp status The TFTP process is idle. Example 2 A500:tftp status A TFTP is in progress from the main console.
  • Page 291 Overview Subcommands Command Description...
  • Page 292 Purpose conmsg Syntax conmsg { consmsgID | v | q Arguments Instructions: A500: conmsg q A500: conmsg v A500: conmsg - msg# conmsg -5 -10. A500: conmsg +msg# conmsg +5 +10. conmsg -5 conmsg +5...
  • Page 293 exec Purpose exec Syntax exec { file_name } Arguments Example...
  • Page 294 Purpose pang Syntax pang { IP Address } Arguments Example A500: pang 198.3.108.153 Attempting to ATM ping 198.3.108.153 ATM Ping: Success... ping pang...
  • Page 295 Syntax ping { IP Address } Arguments Example A500:ping 198.3.104.45 ping 198.3.104.45... 120 bytes from 198.3.104.45: seq=0, 1 ticks 120 bytes from 198.3.104.45: seq=1, 1 ticks 120 bytes from 198.3.104.45: seq=2, 1 ticks 120 bytes from 198.3.104.45: seq=3, 0 ticks 120 bytes from 198.3.104.45: seq=4, 1 ticks...
  • Page 296 Purpose status Syntax status Arguments Example A500:status System Status A500 ATM Switch Software 3.0 Copyright 1996, 1997 Lucent Technologies Built Mon Jan 4 15:13:56 EST 1999 __________________________________________________ System name System time/date System Uptime Ethernet IP address Ethernet IP mask...
  • Page 297 Output Description Field Description Values...
  • Page 298 Purpose telnet Syntax telnet { ip address } Arguments Example A500:telnet 198.3.104.45 Connected login: Greyhound A500 System Console (c) 1999 Lucent Technologies...
  • Page 300 Events...
  • Page 301 tftp setserver admin address status show system configuration...
  • Page 302 show system configuration...
  • Page 314 viewing signaling esi remove admin ack_alarms admin address admin changeboot admin changename admin changeprompt admin contact admin downInterface admin gateway admin guestpasswd admin inband address admin interface admin link_type admin location admin nvram backup admin nvram defragment admin nvram reset admin nvram restore admin passwd admin peergroupid...
  • Page 316 NVRAM clearing contents viewing admin exec file help modify pang ping show tftp consolerc...
  • Page 317 deleting ESIs using the CLI file cat file cp file cr file edit file erase file info file ls file rm file...
  • Page 318 on a server...
  • Page 319 viewing viewing conmsg exec pang ping status misc resetting when lost modify add_channel multipoint modify add_channel point-point modify add_path multipoint modify add_path point-point modify atmprefix modify console autologout modify console timeout modify rem_channel modify rem_path modify...
  • Page 320 setting viewing viewing...
  • Page 321 Local IP address PAP required Peer IP address Subnet Mask figure of viewing using the CLI setdialout teleNum...
  • Page 322 pnni mib scope ethernet showIB ethernet showregs ethernet showrings lec config lec status link_type pnni hmap pnni mib addmap pnni mib base pnni mib interface pnni mib link pnni mib map pnni mib metrics pnni mib nmap pnni mib npeerport pnni mib npeert pnni mib pgl pnni mib ptse...
  • Page 323 stats memstat stats portstat stats queuestat stats sar stats swstat switch busy_vcis switch cdvt switch chipversions switch circuittable switch epd switch free_vcis switch maxvci switch queue capacities switch queue global system alarms system bootSource system chassis system community system configuration system crash_info system eventlog system interfaces...
  • Page 324 status sync diag dext sync diag dline sync diag dprov sync disable sync enable sync mode holdover sync mode lock sync setsync sync status sync entering viewing telnet...
  • Page 325 tftp get tftp setserver tftp status tftp displaying system alarms system signaling info viewing statistics signaling...

This manual is also suitable for:

Cajun a500

Table of Contents