Switch with 1b processor attached processor interface frame (208 pages)
Summary of Contents for Lucent Technologies A500
Page 1
Lucent Cajun A500 ATM Switch User Guide Release Part #: 49080007...
Page 2
Cajun P550, Cajun A500, Lucent Definity ATM ECS, and Lucent MMCX are trademarks of Lucent Technologies. The following products are trademaked by their respective companies: Bay Networks, Cisco, Fore, 3COM, Sun, HP, Compaq, and Microsoft.
Page 12
System Output passwd greyhound Unit 2 Port 2 admin...
Page 17
M A K E R ETHER TC P Telnet UD P TFTP LANE CA C...
Page 19
P N N I R o u tin g Task ILMI C all C o n tro l Task Task U N I/P N N I S ig n alin g Task S w itch M o n /C trl C h assim o n TA S K Snooping...
Page 22
LANE A500 Server Ethernet Management A500 Station Cloud A500...
Page 23
Mini-Bridge Local Ethernet VCCs to other A500s 'HVLJQDWHG$ MAC – IP – Port Mapping Table (MIPM) Proxy-ARP Handler «...
Page 24
G eneric O perating S ystem Interface O perating S ystem A daptation Layer Tim er M anager B uffer M anager H igh Level I/O Interface O ther M isc F unctions pR O B E + pS O S + D evice D river...
Page 25
Process A Process B Network Protocols (e.g., TCP/IP, UDP/IP) lfTxFrame/lfhISR Driver SOCKET Ether Driver...
Page 29
R outing U N I M gm t Task Task S ig naling Task C h assim on Task S w itc h M o n /C trl Snooping Task LEGEND Data Control ... L ocal D irect M od em C onsole C onso le Task S N M P...
Page 31
TIMEOUT 3 ABORT NO\sCARRIER ABORT BUSY ABORT NO\sDIALTONE \N AT OK ATDT\T CONNECT \N login: \U password:...
Page 32
To/From pNA (IP) PPP actually provides NI interface Link Control Protocol Authentication HDLC Serial Port Modem IP Control Protocol Ip Control Protocol PPP provides modem support also in the form of scripts.
Page 38
Management Station Separate web server serves on-line help and bitmaps. Switch serves page content and receives responses.
Page 44
AX500: admin address Enter IP Address [198.3.104.162]: 198.3.104.163 Enter IP Mask [255.255.255.0]: 255.255.255.0 New IP Address and Mask will be used when A500 is rebooted modify default gateway AX500: modify default gateway Enter IP gateway[198.3.104.240]:198.3.104.240 Default Gateway will be used when A500 is rebooted.
Page 73
Enter login: root password: A500: show show ? A500:...
Page 74
Show Static-IP status [ server ] Show Static-IP server information [ client ] Show Static-IP client information admin static_ip rem_client ? A500: admin static_ip rem_client ? admin static_ip rem_client [admin static_ip rem_client {clientNum}] A500: show system interfaces A500: sh sy i show...
Page 76
Are you sure you want to reboot? {verb} {object} {info_type} [target_object] [data] A500: admin link_type Select ATM port (A1.1 - A4.8): admin link_type a1.1...
Page 77
A500: admin link_type a1.1 A500: admin link_type Select a configuration for port A1.1: 1) Standard UNI 3.0 2) Standard UNI 3.1 3) IISP Network 4) IISP User 5) Lucent Network Signaling 6) No Signaling 7) Custom... Enter selection: 5 Setting port A1.1 to Lucent Network Signaling...
Page 78
198.3.104.162 A500: tftp get directoryname /SWP_IMAGE.IMG Destination [PCMCIA:SWP_IMAGE.IMG]: IP address of TFTP Server [198.3.104.129]: FLASH1: consolerc MAIN: config name SWP_IMAGE.IMG nvram.dat. nvram.dat SWP_IMAGE.IMG MAIN: tftp get FLASH1: SWP_IMAGE.IMG nvram.dat...
Page 83
Purpose admin ack_alrams Syntax admin ack_alarms { all | # } Arguments Example A500: admin ack_alarms all...
Page 84
Purpose admin address Syntax admin address { IP address } { subnet mask } Arguments Example A500: admin address Enter IP address[198.3.108.158]: 198.3.108.158 Enter IP mask[255.255.255.0]: 255.255.255.0 New IP address and mask will be used when A500 is rebooted...
Page 85
Purpose admin changename Syntax admin changename [ new_name ] Arguments Example A500: admin changename Enter System name (Blank for none):Greyhound...
Page 87
Purpose admin changeprompt Syntax admin changeprompt { new prompt } Arguments Example A500:admin changeprompt Enter Prompt:Lab1 Lab1:...
Page 88
Purpose admin contact Syntax admin contact { contact name } Arguments Example A500: admin contact jsmith...
Page 89
Purpose admin downInterface Syntax admin downInterface { Arguments Examples A500:admin downInterface a1.1 Bringing down Board 1, port 1 A500:admin downInterface a1.2 0 Bringing down Board 1, port 2, vpi 0 } [ vpi ] port admin link_type...
Page 90
Purpose admin gateway Syntax admin gateway { new_ip_gateway } Arguments Example A500:admin gateway Enter IP gateway[0.0.0.0]: 123.000.103.111 We will clear the A500’s default Gateway IP address Default Gateway will be used when A500 is rebooted. status...
Page 91
Purpose admin guestpasswd help show Syntax admin guestpasswd { Arguments Example A500:admin guestpasswd please enter NEW password (maximum of 8 characters)> please enter NEW password, again> new password has been saved new_password...
Page 92
Purpose admin inband_address Syntax admin inband_address { IP address } { subnet mask } Arguments Example A500: admin inband_address Enter IP address[0.0.0.0]: 198.3.106.111 Enter IP mask[0.0.0.0]: 255.255.255.0 New IP address and mask will be used when A500 is rebooted...
Page 93
Purpose admin interface Syntax admin interface { Arguments Example A500: admin interface a1.1 Select a configuration for port A1.1: 1) SONET 2) SDH Enter selection: 2 port...
Page 95
Select cell rate (10000 - 353207): 10000 Configuring Port A1.8, VPI 0: Auto-configuration, ILMI, Cell Rate 10000, Max VCI 2047 Example 2 A500:admin link_type a1.8 1 2 2046 12345 Configuring Port A1.8, VPI 0: Auto-configuration, ILMI, Cell Rate 112345, Max VCI 2046 (No protocols running) (Auto-configuration) (UNI 3.0 Network)
Page 96
Purpose admin location Syntax admin location [ value ] Arguments Example A500: admin location lab3...
Page 97
Purpose admin nvram backup Syntax admin nvram backup Arguments Example A500: admin nvram backup ## info : loading into PCMCIA - from 0x33c4cd44, to 0x50000000,size=1892 ## info : loading into PCMCIA - from 0x33c4cd44, to 0x50000000,size=1892 NVRAM CRC 0x88bcf233 ## info : loading into PCMCIA - from 0x33c4cd44, to...
Page 98
Arguments Example A500: admin nvram defragment This function will defragment the contents of nvram storage. If the system loses power or is rebooted while the defragment is in progress, the entire contents of nvram may be lost.
Page 99
Syntax admin nvram reset Arguments Example A500: admin nvram reset This function will clear the contents of nvram storage. Things such as IP address and port configuration will need to be reinitialized. Do you want to continue? : [n]y...
Page 101
Purpose admin passwd Syntax admin passwd { Arguments Example A500:admin passwd please enter NEW password (maximum of 8 characters)> please enter NEW password, again> please enter OLD password> new password has been saved new_password current_password...
Page 102
Current Setting : Peer Group ID in NVRAM : 47.00.00.00.00.00.00.00.00.00.00.02.00 Use NVRAM Setting for Peer Group ID when rebooted Example 2 A500:admin peergroupid 47000000000000000000000000 New Pnni Peer Group ID is stored in NVRAM and will take effect upon reboot A500:show pnni node...
Page 103
Purpose admin pnnilevel Syntax admin pnnilevel { value } Arguments Example A500:admin pnnilevel Enter PNNI LEVEL [96]<values 0-104>:100 New PnniLevel [100] will take effect upon reboot...
Page 104
Purpose admin reboot Syntax admin reboot Arguments Example A500: admin reboot Enter 'y' to confirm, 'n' to exit: System Reboot login:...
Page 105
Purpose admin readcommunity Syntax admin readcommunity { community name } Arguments Example A500: admin readcommunity Enter system read community:public This parameter will not be used until a subsequent reboot...
Page 106
Purpose admin signaling esi add Syntax admin signaling esi add { port } { vpi } { address } Arguments Example A500: admin signaling esi add a1.8 0 11.11.11.11.11.11 added address 47.00.01.11.11.00.04.00.00.01.00.03.01.11.11.11.11.11.11.00 to port a1.8 vpi 0...
Page 107
Purpose admin signaling esi remove Syntax admin signaling esi remove { port } { vpi } { address } Arguments Example A500: admin signaling esi remove a1.8 0 11.11.11.11.11.11 removed address 47.00.01.11.11.00.04.00.00.01.00.03.01.11.11.11.11.11.11.00 to port a1.8 vpi 0...
Page 116
Purpose admin switch cdvt Syntax admin switch cdvt { port } { value | default } Arguments Example A500:admin switch cdvt a1.1 250 cdvt for port a1.1 will be 250 microseconds at reboot...
Page 117
Syntax admin switch epd enable/disable Arguments Example 1 A500: admin switch epd enable Early Packet Discard is enabled with a queue threshold of 7/8 Example 2 A500: admin switch epd disable Early Packet Discard is disabled admin switch epd enable and admin...
Page 118
Purpose admin switch epd threshold Syntax admin switch epd threshold { value (1-7) } Arguments Example A500: admin switch epd threshold 7 Early Packet Discard queue threshold updated to 7/8...
Page 119
Purpose admin switch queue capacity Syntax admin switch queue capacity { port } { queue (1-4) } { value } Arguments Example A500: admin switch queue capacity a1.1 3 1000 port A1.1, queue 3: updated, new queue capacity is 767...
Page 120
admin switch queue global Purpose admin switch queue global admin switch queue capacity Syntax admin switch queue global { queue (1-4) } { value } Arguments Example show switch queue global...
Page 121
Purpose admin switch maxvci Syntax admin switch maxvci { Arguments Example A500:admin switch maxvci a1.1 1790 maxvci for port a1.1 will be 1790 at reboot } { value | default } port...
Page 122
Purpose admin telnetflag Syntax admin telnetflag Arguments Example A500: admin telnetflag Telnet sessions are enabled Do you want to change it? : [n]...
Page 123
Purpose admin trapcommunity Syntax admin trapcommunity { community name } Arguments Example A500:admin trapcommunity Enter system trap community:support This parameter change will not be used until a subsequent reboot...
Page 124
Purpose admin trapdestination Syntax admin trapdestination { IP address } Arguments Example A500:admin trapdestination Enter IP address[]:198.0.000.00 This parameter change will not be used until a subsequent reboot...
Page 125
Bringing up Board 1, port 3 Bringing up Board 1, port 3 Example 3 A500:admin ack_alarms all A500:admin upInterface a1.1 0 Bringing up Board 1, port 1, vpi 0 ********** New System Alarms ********** [27] Administrative Status of port brought up...
Page 126
Purpose admin time Syntax admin time { dd mm yy hh mm } Arguments Example A500:admin time 12 05 98 17 02 The current system date is Tuesday, May 12, 1998 5:02:00p...
Page 127
Purpose admin writecommunity Syntax admin writecommunity { community name } Arguments community name Example A500:admin writecommunity Enter system write community:admin This parameter change will not be used until a subsequent reboot Admin...
Page 139
Purpose file info Syntax file info Arguments Example A500: file info +------------------------------------+ MANUFACTURERS CODE +--------------+---------------------+ |Tuple offset +--------------+---------------------+ | 50000000 | 50000002 | 50000004 | 50000006 +--------------+---------------------+ Value:...
Page 140
Purpose file ls Syntax file ls [ -a ] Arguments Example A500: file ls -a File Name --------------------------------------------------------------------- consolerc manifest snmpd.cnf notifyrc acl.pty agt.pty context.pty view.pty wiring script mark FLASH1: SWP_IMAGE.IMG this PCMCIA card is owned by labtech SWP_IMAGE.IMG...
Page 141
Output Description Field Description Values...
Page 152
Example A500: modify add_path point-point input port _ a1.1 input vpi _ 100 output port _ a2.2 output vpi _ 200 service class _ cbr input peak cell rate _ 100000 output peak cell rate _ 100000 vpi connection added to switch table...
Page 153
Purpose Syntax modify atmprefix { new_prefix } Arguments Example A500: modify atmprefix 390000000000000000C60368A0 New ATM prefix will be used when platform is rebooted modify atmprefix...
Page 154
Purpose modify console autologout Syntax modify console autologout { on | off } Arguments Example A500: modify console autologout on...
Page 155
Purpose modify console timeout Syntax modify console timeout { value } Arguments Example A500: modify console timeout 5...
Page 162
Purpose ppp display Syntax ppp display Arguments Example A500:ppp display PPP is enabled PPP down! PPP Local IP Address ---------------- address 192.168.55.1 mask 255.255.255.0 Dial Out Configuration ---------------- Dial Out virtual PPP channel is not being used DialOut User Name:...
Page 168
Purpose ppp setCHAP Syntax ppp setCHAP { hostname | secret } Arguments Example A500:ppp setCHAP dialup server name...
Page 169
Syntax ppp setdialin authentIn { PAP | CHAP } Arguments Example 1 A500:ppp setdialin authentIn PAP Do you want to use Password Authentication Protocol (PAP):[n] Example 2 A500:ppp setdialin authentIn CHAP Do you want to use Challenge Handshake Authentication Protocol...
Page 170
Purpose ppp setdialin peerIPIn Syntax ppp setdialin peerIPIn { IP address } Arguments Example A500:ppp setdialin peerIPIn...
Page 171
Syntax ppp setdialout authentOut { PAP | CHAP } Arguments Example 1 A500:ppp setdialout authentOut PAP Do you want to use Password Authentication Protocol (PAP):[n] Example 2 A500:ppp setdialout authentOut CHAP Do you want to use Challenge Handshake Authentication Protocol...
Page 172
Purpose ppp setdialout delay_timer Syntax ppp setdialout delay_timer { hours | minutes } Arguments Example A500:ppp setdialout delay_timer Current delay timer value: 0 hours and 0 minutes Enter hours:0 Enter minutes:5...
Page 173
Purpose ppp setdialout peerIPOut Syntax ppp setdialout peerIPOut { IP address } Arguments Example A500:ppp setdialout peerIPOut...
Page 174
Purpose ppp setdialout pppModeOut Syntax ppp setdialout pppModeOut { 1 | 2 } Arguments Example 1 A500:ppp setdialout pppModeOut Select mode for dial out port: 1)PPP mode Active 2)Virtual dial out port not used Enter selection:...
Page 175
Purpose ppp setdialout namePassOut Syntax ppp setdialout namePassOut { name | password } Arguments Example A500:ppp setdialout namePassOut...
Page 176
Purpose ppp setdialout teleNum Syntax ppp setdialout teleNum { number } Arguments Example A500:ppp setdialout teleNum DialOut Telephone Number: Do you want to change it?:[n]y Enter 20 character or less telephone number:18881234567...
Page 177
Syntax ppp setPAP { username | password | message } Arguments Example A500: ppp setPAP password index 1 - user name:my_name password:******* message:LOGIN OK password index 2 - empty table entry Enter desired index (default is no changes):1...
Page 178
Current local ppp address is:192.000.00.0 Do you want to change the local ppp IP address?:[n]y Enter IP address in dotted decimal form:192.111.11.1 Please reboot A500 or cycle modem power when finished editing ppp configuration Current local ppp IP subnet mask is:255.000.000.0 Do you want to change the local ppp IP subnet mask?:[n]y Enter subnet mask in dotted decimal form:255.111.111.1...
Page 180
Overview show Subcommands Command Description...
Page 187
Purpose show lec config Syntax show lec config Arguments Example A500:show lec config LEC Configuration ================= Initialization Method:Use well known LECS address. Manual LES ATM Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 ELAN Name:...
Page 188
Purpose show lec status Syntax show lec status Arguments Example A500:show lec status LEC Status ========== LEC ID:0 LECS Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 LES Address:00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 State:Initial ELAN Name:...
Page 189
Purpose show link_type Syntax show link_type { port } Arguments Example A500:show link_type a2.4 Port VPI Protocol(s) ---- --- ------------------------ ------- ---- A2.4 0 Auto-configuration, ILMI 0353207 65535 Rate...
Page 190
Purpose show pnni hmap Syntax show pnni hmap Arguments Example A500:show pnni hmap ***** PNNI HMAP INFORMATION ***** ====================================================================== ======== 60a0390000000000000000c0a84b230020b6171b0000 390000000000000000c0a84b230020b6171b0000 NODE ID ATM Address...
Page 191
Purpose show pnni neighbor Syntax show pnni neighbor Arguments Example A500:show pnni neighbor ***** PNNI NEIGHBOR INFORMATION ***** Port ID ====================================================================== Link State Remode Node ID...
Page 192
Purpose show pnni base Syntax show pnni base Arguments Example A500:show pnni base PNNI Base Group keepgoing = 0x1 pnniHighestVersion pnniLowestVersion pnniDtlCountOriginator pnniDtlCountBorder pnniCrankbackCountOriginator pnniAltRouteCountBorder pnniAltRouteCountOriginator pnniAltRouteCountBorder pnniRouteFailCountOriginator pnniRouteFailCountBorder pnniRouteFailUnreachableOriginator pnniRouteFailUnreachableBorder 4000 4000...
Page 193
Purpose show pnni node mib Syntax show pnni node mib Arguments Example A500:show pnni node mib ***** PNNI NODE INFORMATION ***** Level Node ID (HEX) Peer Group ID (HEX) : 60390000000000000000c0a84b00 ATM Address (HEX) : 96...
Page 214
Purpose show pnni mib svccrcc Syntax show pnni mib svccrcc Arguments Example A500:show pnni mib svccrcc PNNI SVCC RCC Table keepgoing = 0x6...
Page 215
Purpose show pnni mib tnsmap Syntax show pnni mib tnsmap Arguments Example A500:show pnni mib tnsmap PNNI Map TNS Table keepgoing = 0x6...
Page 216
Purpose show pnni node Syntax show pnni node Arguments Example A500:show pnni node ***** PNNI NODE INFORMATION ***** Level Node ID (HEX) Peer Group ID (HEX) : 60390000000000000000c0a84b00 ATM Address (HEX) : 96 : 60a0390000000000000000c0a84b230020b6171b0000 : 390000000000000000c0a84b230020b6171b0000...
Page 217
Purpose show pnni rouadd Syntax show pnni rouadd Arguments Example A500:show pnni rouadd ***** PNNI ROUTE ADDRESS INFORMATION ***** ********* ADDRESSES LEARNED FROM LOCAL AND MANAGEMENT PROTOCOL *********** Address ============================================================================ 39000000000000000001010105000000000000 39000000000000000001010106000000000000 390000000000000000c0a84b230020b6171b00 ************ ADDRESSES LEARNED FROM PNNI PROTOCOL ***************...
Page 218
Purpose show ppp Syntax show ppp Arguments Example A500:show ppp PPP is enabled PPP down! PPP Local IP Address ---------------- address 192.168.55.1 mask 255.255.255.0 Dial Out Configuration ---------------- Dial Out virtual PPP channel is not being used DialOut User Name:...
Page 219
Purpose show signaling cause Syntax show signaling cause { cause # } Arguments Example 1 A500:show signaling cause 2 Cause 2: No route to specified transit network Example 2 A500:show signaling cause Cause ----- --------------------------------------------------- Unallocated (unassigned) number...
Page 220
No VPCI/VCI available Resource unavailable, unspecified Quality of Service unavailable User cell rate not available Call cleared due to change in PGL Bearer capability not authorized Bearer capability not presently available Service or option not available, unspecified Bearer capability not implemented Unsupported combination of traffic parameters Invalid call reference value Identified channel does not exist...
Page 221
Purpose show signaling esi Syntax show signaling esi Arguments Example A500:show signaling esi Number of ESI's Allowed: 32 Current number of ESI's: 0 port ---------- ---- ----...
Page 222
Purpose show signaling routes Syntax show signaling routes Arguments Example A500:show signaling routes Number of Local Static Routes Allowed: 32 Number of Local Static Routes Allowed: 32 Current number of Local Static Routes: 2 Port Address ---- ----------------------------------------------------------- A?.?
Page 223
Purpose show signaling stats Syntax show signaling stats { vpi } { port } Arguments Example A500:show signaling stats 35 a1.1 Signaling Statistics Port A1.1 if_index = 0x1010000 sscop con events = 3 sscop errored pdus = 1 received setup attempts = 0...
Page 224
SSG STATISTICS reset ssg stats = 0 parse statistics no of messages received with invalid protocol discriminator = 0 no of messages received with call reference length errorsi = 0 SETUP messages received with call reference flag incorrectly set to 1=0 no of invalid call reference = 0 no of unrecognized messages received with pass along bit set = 0 no of unrecognized messages received and discarded = 0...
Page 225
Error Recovery PDUs - num trans = 0 - num rcvd = 0 - num retrans rcvd = 0 - num retrans trans = 0 - num acks trans = 0 - num acks rcvd = 0 - num rej rcvd = 0 - num rej trans = 0 End PDUs - num trans = 1...
Page 226
Syntax show signaling summary [ port ] [ vpi ] Arguments Examples A500:show signaling summary Link Phy Admin ILMI Port VPI Config State State State ---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- A1.1 0...
Page 227
---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- ---- - A1.1 0 Auto Down A1.1 100 UNI4.0 Down A500:show signaling summary a1.1 100 Link Admin Port VPI Config State State ---- --- ------ ----- ----- ----------- ----------- ---- ---- -------- ---- - A1.1 100 UNI4.0 Down...
Page 228
ILMI states: ------------ DOWN -> ilmi state machine is not running, port/vpi is admin down INITIALIZIN -> ilmi process is being initialized INITIALIZED -> ilmi process has completed initialization CONNECTED -> ilmi process has connected to a remote peer CONFIGURED ->...
Page 229
Purpose show static_ip client Syntax show static_ip client Arguments Example A500:show static_ip client Client address: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00...
Page 230
Purpose show static_ip server Syntax show static_ip server Arguments Example A500:show static_ip server Server address: 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00...
Page 231
Purpose show static_ip status Syntax show static_ip status Arguments Example A500:show static_ip status Static-IP Status ================ Current Status: Current Mode: Nvram Status: Nvram Mode: DISABLED CLIENT DISABLED CLIENT...
Page 232
Purpose show stats cellstat Syntax show stats cellstat Arguments Example A500: show stats cellstat ------------------------------------ Current Switch Cell Statistics ------------------------------------ Priority 1 cells = Priority 2 cells = Priority 3 cells = Priority 4 cells = total cells...
Page 233
Purpose show stats errether Syntax show stats errether Arguments Example A500: show stats errether T_DSCRDS T_COLL -------- ------ R_DSCRDS R_MISSED -------- -------- Output Description Field T_CAR T_RETRY T_BABBLE ----- ------- -------- R_COLL R_RUNT ------ ------ Description Values...
Page 234
Purpose show stats errsar Syntax show stats errsar Arguments Example A500: show stats errsar Port HW Err ---- -------- A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A2.1 A2.2 A2.3 A2.4 A2.5 A2.6 A3.1 A3.2 A3.3 A3.4 A3.5 A3.6 A4.1...
Page 236
Purpose show stats ether Syntax show stats ether Arguments Example A500: show stats ether ETHERNET PORT In Octets In Unicast Frames ---------- ----------------- Out Octets Out Unicast Frames ---------- ----------------- Output Description Field In NUnicast Frames ------------------...
Page 237
Purpose show stats memstat Syntax show stats memstat Arguments Example A500: show stats memstat LUT Memory Management Statistics -------------------------------- vc slots vp slots free slots ITT Memory Management Statistics -------------------------------- free slots in-use slots OPT Memory Management Statistics...
Page 239
Syntax show stats queuestat { port | all } Arguments Example A500: show stats queuestat a1.1 Port A1.1 Queue Statistics -------------------------------- priority 1: input enabled, output enabled, cell count = 0 priority 2: input enabled, output enabled, cell count = 0...
Page 240
Purpose show stats sar Syntax show stats sar Arguments Example A500: show stats sar Port In Octets ---- --------- Output Description Field Out Octets In PDUs Out PDUs ---------- --------- ---------- 1127651 25904 Description...
Page 241
Purpose show stats portstat Syntax show stats portstat { port } Arguments Example A500: show stats portstat <port#> _ a1.2 Sonet per Port Statistics --------------------------------- Receive Cell Count: Transmit Cell Count: Section Level Bit Err: Line Bit Err:...
Page 242
Output Description Field Description Values...
Page 243
Purpose show stats swstat Syntax show stats swstat Arguments Example A500: show stats swstat --------------------------------------- Cumulative Switch Cell Statistics --------------------------------------- discarded cells invalid cells Output Description Field Description Values...
Page 244
Purpose show switch busy_vcis Syntax show switch busy_vcis { port } { vpi } Arguments Example A500: show switch busy_vcis a1.2 0 Busy vcis for port A1.2, VPI --------------------------------...
Page 245
Purpose show switch cdvt Syntax show switch cdvt { port | all } Arguments Example A500:show switch cdvt a1.1 A1.1 cell delay variation tolerance values ------------------------------------------ current cdvt for port reboot cdvt for port 250 microseconds 250 microseconds...
Page 246
Purpose show switch chipversions Syntax show switch chipversions Arguments Example A500: show switch chipversions white chip version = 2 grey chip version = 2 pif chip version numbers: port A1.1...not available port A1.2...not available port A1.3...not available port A1.4...not available...
Page 247
Purpose show switch circuittable Syntax show switch circuittable [ all | port # ] Arguments Example A500: show switch circuittable ___________________________________________________________________ Input |port vpi vci| port vpi |_____________|______________|______________________________________ A1.1 A1.1 A1.3 A1.5 100 A1.6 A1.8 Output Connection vci| type class A1.8...
Page 248
Output Description Field Description Values...
Page 249
Purpose show switch epd Syntax show switch epd Arguments Example 1 A500: show switch epd Early Packet Discard is enabled with a queue threshold of 7/8 Example 2 A500:sh switch epd Early Packet Discard is disabled...
Page 250
Purpose show switch free_vcis Syntax show switch free_vcis { port } { vpi } Arguments Example A500: show switch free_vcis port _ a1.2 VPI _ 0 Free vcis for port A1.2, VPI -------------------------------- 102, 103, 104, 112,...
Page 251
Purpose show switch maxvci Syntax show switch maxvci [ port ] Arguments Example A500:show switch maxvci a1.1 A1.1 maximum vci values ----------------------- current maximum vci for port reboot maximum vci for port admin switch maxvci 2015 1790...
Page 252
Purpose show switch queue capacities Syntax show switch queue capacities { port | all } Arguments Example A500: show switch queue capacities a1.1 Queue Cell Capacities For Port A1.1 ----------------------------------- priority 1: priority 2: priority 3: priority 4:...
Page 253
Purpose show switch queue global Syntax show switch queue global Arguments Example A500: show switch queue global Global Queue Cell Capacities For Switch --------------------------------------- global queue 1: global queue 2: 65535 cells global queue 3: global queue 4: 49152 cells...
Page 254
Purpose show system alarms Syntax show system alarms Arguments Example A500: show system alarms Current System Alarms --------------------- [1] Failed to fetch configuration files [4] Power Supply failure [28] Board Removed show system alarms...
Page 255
Purpose show system bootSource Syntax show system bootSource Arguments Example A500: show system bootSource NVRAM boot source: Boot device [PCMCIA:] file [SWP_IMAGE.IMG] offset [0x0]...
Page 256
Purpose show system chassis Syntax show system chassis Arguments Example A500:show system chassis _________________________________________________ __________________________________________________ Power supply 1... Not installed Power supply 2... OK AC Power 2... OK DC Power 2... OK PHY Slot 1 ... Present PHY Slot 2 ...
Page 257
Output Description Field Description Values...
Page 258
Purpose show system community Syntax show system community Arguments Example A500: show system community Read Community: techpub Write Community: sysadmin Trap Community: engineer...
Purpose show system configuration Syntax show system configuration Arguments Example A500: show system configuration __________________________________________________ __________________________________________________ A500 name IP address IP mask A500 address A500 ATM address 39.0000.000000000000C60368B0.0020B616E400.00 Console timeout in minutes Cajun A500 Database -- A500 -- 198.3.104.176...
Page 260
Syntax show system crash_info { all | last | num | Arguments Example A500: show system crash_info all Crash occured because of NMI Running A500 software version: UNOFFICIAL Crash occured on 3/19/99 at 17:29:18 SWP: g: 0x30292180 0x31EF293C 0x00000000 0x00000064...
Page 261
Purpose show system eventlog Syntax show system eventlog Arguments Example A500: show system eventlog System up time ---------------- 0:00:54.78 Event ----------------------------------------- Succeeded fetching configuration files...
Page 262
Purpose show system interfaces Syntax show system interfaces Arguments Example A500: show system interfaces Device Oper Status _________________________________________________________________ Self Self Output Description Field Admin State Type Status present PROPVIRTUAL present Description Values...
Page 263
Purpose show system que Syntax show system que Arguments Example A500: show system que Port ------------------------------------ ETHER 0/64 0/64 Output Description Field TxFQ RxFQ 64/64 0/64 64/64 64/64 0/64 64/64 Description Values...
Page 264
Purpose show system seeprom bp_base Syntax show system seemprom bp_base Arguments Example A500:show system seeprom bp_base A500 MAC Address: Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 0:20:b6:17:1a:0 10010062...
Page 265
Purpose show system seeprom bp_card Syntax show system seemprom bp_card Arguments Example A500:show system seeprom bp_card Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010011 ÿ ÿÿ ÿÿ ÿÿ...
Page 266
Purpose show system seeprom bp_chassis Syntax show system seemprom bp_chassis Arguments Example A500:show system seeprom bp_chassis Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010033 ÿ ÿÿ ÿÿ ÿÿ...
Page 267
Purpose show system seeprom phy# Syntax show system seemprom phy# Arguments Example A500: show system seeprom phy2 Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010160 ÿÿ ÿÿÿÿÿ ÿÿÿÿ...
Page 268
Purpose show system seeprom swf Syntax show system seemprom swf Arguments Example A500:show system seeprom swf Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number:...
Page 269
Purpose show system seeprom swp Syntax show system seemprom swp Arguments Example A500: show system seeprom swp A500 MAC Address: Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 0:20:b6:14:de:0 ÿÿÿÿÿÿÿÿ...
Page 270
Purpose show system seeprom swp Syntax show system seemprom sync Arguments Example A500:show system seeprom sync Board Part number: Board Rev. number: Board P.O. number: Board Date Code: Board Serial number: 10010121 Stratum 3/4 ÿ ÿÿ...
Page 271
Purpose show system stack Syntax show system stack Arguments Example A500:show system stack IfIndex ____________________________________________________________ Higher Lower Status...
Purpose show time Syntax show time Arguments Example A500:show time The current system date is Tuesday, April 6, 1999 2:35:23p...
Page 273
Purpose show trapinfo Syntax show trapinfo Arguments Example A500:show trapinfo Trap Community public Trap Destination IP address 192.168.75.22...
Purpose show users Syntax show users Arguments Example A500:show users Device Login Name ------ ---------- Type From ------ ----------------- root Telnet nnn.n.nnn.nn root Direct...
Purpose show version Syntax show version Arguments Example A500: show version IMAGE VERSIONS LoadedImage ----------- --------------- -------- PCMCIAImage ----------- --------------- -------- PCMCIA:SWP FLASH1Image ----------- --------------- -------- FLASH1:SWP Version Date 3.00 01/04/99 Version Date 3.00 01/04/99 Version Date ACE_100.15...
Page 281
Purpose sync enable/disable Syntax sync enable sync disable Arguments Example 1 A500:sync enable This Function will enable the sync card and reboot the system Do you want to continue? : [n]y Enabling sync card ... System Reboot ... Example 2...
Page 282
Syntax sync mode holdover sync mode lock Arguments Example 1 A500:sync mode holdover This Function commands the sync card to go to holdover mode Do you want to continue? : [n]y Successful Example 2 A500:sync mode lock This Function commands the sync card to go to locked mode...
Purpose tftp get Syntax tftp get { file_name Arguments Example A500: tftp get SWP_IMAGE.IMG PCMCIA:SWP_IMAGE.IMG 192.3.11.129 Attempting to TFTP file from host 192.3.11.129 Source: SWP_IMAGE.IMG Destination: PCMCIA:SWP_IMAGE.IMG Starting Server located. Bytes received: Done. File 'SWP_IMAGE.IMG' - 1062811 bytes - received.
Page 288
Purpose tftp setserver Syntax tftp setserver { Arguments Example A500:tftp setserver TFTP Server IP address _ 198.3.111.246 The new address will be used on the next TFTP request. server_IP_address...
Purpose tftp status Syntax tftp status Arguments Example 1 A500:tftp status The TFTP process is idle. Example 2 A500:tftp status A TFTP is in progress from the main console.
Page 294
Purpose pang Syntax pang { IP Address } Arguments Example A500: pang 198.3.108.153 Attempting to ATM ping 198.3.108.153 ATM Ping: Success... ping pang...
Page 295
Syntax ping { IP Address } Arguments Example A500:ping 198.3.104.45 ping 198.3.104.45... 120 bytes from 198.3.104.45: seq=0, 1 ticks 120 bytes from 198.3.104.45: seq=1, 1 ticks 120 bytes from 198.3.104.45: seq=2, 1 ticks 120 bytes from 198.3.104.45: seq=3, 0 ticks 120 bytes from 198.3.104.45: seq=4, 1 ticks...
Page 296
Purpose status Syntax status Arguments Example A500:status System Status A500 ATM Switch Software 3.0 Copyright 1996, 1997 Lucent Technologies Built Mon Jan 4 15:13:56 EST 1999 __________________________________________________ System name System time/date System Uptime Ethernet IP address Ethernet IP mask...
Page 297
Output Description Field Description Values...
Page 298
Purpose telnet Syntax telnet { ip address } Arguments Example A500:telnet 198.3.104.45 Connected login: Greyhound A500 System Console (c) 1999 Lucent Technologies...
Page 323
stats memstat stats portstat stats queuestat stats sar stats swstat switch busy_vcis switch cdvt switch chipversions switch circuittable switch epd switch free_vcis switch maxvci switch queue capacities switch queue global system alarms system bootSource system chassis system community system configuration system crash_info system eventlog system interfaces...
Need help?
Do you have a question about the A500 and is the answer not in the manual?
Questions and answers