Lucent Technologies CBX 3500 Configuration Manual page 673

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Beta Draft Confidential
Table 18-3.
E.164 (Native)
DCC and ICD AESA
(or Anycast)
E.164 AESA
(or Anycast)
Custom AESA
3. To configure a new port address, use the instructions
4. Select the Non-call Initiator For FRF.5 FR-SPVC check box if this endpoint is not
5. Choose OK. The Offnet EndPoint Selection dialog box will close and the Add
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Selecting the Address Formats and Configuring the
Offnet PVC Terminating Endpoint Address
Address Format
In the
represent the E.164 address. The value you enter is then
converted to the ASCII hex values that represent each digit in the
number (this value is displayed in the Address).
In the DCC field, enter the data country code (DCC) of the
country in which the address is registered, or the International
Country Designator (ICD) that identifies the international
organization to which this address applies. DCCs and ICDs
consist of 4 hex digits, and occupy two octets. Then enter the
appropriate HO-DSP, ESI, and SEL values in those fields.
In the E.164 field, enter the full or partial E.164 AESA address.
Since the initial domain identifier (IDI) portion of the address is 8
octets (16 hex digits), but the E.164 address format is a maximum
of 15 digits, you must terminate the IDI portion with Fh. For
example, 5085551234 should be entered as 000005085551234F.
After entering in the IDI portion of the address, enter the
appropriate HO-DSP, ESI, and SEL portions to complete the
address.
In the AFI field, enter the custom authority and format identifier
(AFI) you want to use.
Then enter the customized address format you want to use,
starting with the HO-DSP, and followed by the ESI and SEL
values (in that order). This address must be the full 19 octets (38
hex digits) long, with 12 octets used for the HO-DSP, 6 octets
used for the ESI, and 1 octet used for the SEL.
Addresses" on page
17-55.
the call initiator in the circuit. The Address Components field in the Select
Address tab will be cleared since this information will not be needed.
Offnet Circuit dialog box appears
Defining a Point-to-Point Offnet Circuit Connection
Address Components
Prefix field
, enter all of the 1-15 ASCII digits that
(Figure 18-3 on page
Configuring SPVCs
"Configuring SVC Port
18-10).
1/19/0518-9