Lucent Technologies CBX 3500 Configuration Manual page 466

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Configuring ATM PVCs
Configuring Frame Relay-to-ATM Interworking Circuits
10-521/19/05
Table 10-11. Add PVC: Administrative Tab Fields
(FR-ATM) (Continued)
Field
Resource
Determines how PVC traffic is managed during trunk overflow or
Partitioning:
failure conditions. This feature is used with VPNs. For more
Network
information about VPNs, see
Overflow
VPNs."
Select one of the following options:
Public – (default) PVCs are routed over dedicated VPN trunks.
However, in the event of failure, the customer's traffic is allowed
to run over common trunks (shared by a variety of different
customers).
Restricted – PVCs can only use dedicated VPN trunks. A
customer using this mode must purchase redundancy trunks to be
used in the event of outages or other trunk failures.
Path Trace
Enable Path Trace
Enable or disable the path trace feature for this circuit.
Check the box to enable path trace at the switch initializing the
circuit or clear the check box (default) if you do not want to have
path trace enabled.
Clear Call at
Enable or disable the removal of this circuit after the path trace is
Destination
complete.
Selec the check box for the circuit to be deleted from the switch
after the specified path trace timeout period. Path trace
information for this circuit will also be made available for the
timeout period. If you wish for the circuit to remain, clear the
check box (default).
If this field is enabled, the circuit will not be created in the
PRAM. Navis EMS-CBGX will create a temporary circuit. After
the creation of this circuit, no modifications can be made to it.
CrankBack Info
Enable or disable collection of crankback information.
Required
Select this check box to collect and maintain the crankback
information on the traced path. If you clear the checkbox
(default), the crankback information will not be collected.
Pass Along
Enable or disable pass along request for this path trace.
Request
Select the check box (default) to have the path trace continue
through nodes that do not support the path trace feature, causing
the trace results to contain some gaps.
Clear the check box to cause the path trace to terminate at any
switch that does not support the path trace feature. A partial path
trace will be returned.
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Beta Draft Confidential
Action/Description
Chapter 13, "Configuring Layer 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbx 500Gx 550B-stdx 9000

Table of Contents