Lucent Technologies CBX 3500 Configuration Manual page 493

Hide thumbs Also See for CBX 3500:
Table of Contents

Advertisement

Beta Draft Confidential
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Table 10-16. Add Point-to-Multipoint PVC Root: Traffic Type Tab
Fields (Continued)
Field
Priority
Select one of the following circuit priority options from the
(VBR-NRT and
pull-down list:
VBR-RT QoS
1 – (default) high priority
classes only)
2 – medium priority
3– low priority
4– lowest priority.
Traffic Descriptor
Select one of the following TD options from the pull-down list:
Type
PCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes PCR CLP=0. If so, specify the PCR in
CPS for high-priority traffic (that is, the CLP=0 cell stream).
PCR CLP=0+1 (cells/sec) – Specify the PCR in CPS for the
combined high- and low-priority traffic (that is, the CLP=0+1
aggregate cell stream).
SCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes SCR CLP=0. If so, specify the SCR in
CPS for the combined high-priority traffic (that is, the CLP=0
cell stream).
SCR CLP=0+1 (cells/sec) – Displays only if you selected a TD
combination that includes SCR CLP=0+1. If so, specify the SCR
in CPS for the combined high- and low-priority traffic (that is,
the CLP=0+1 aggregate cell stream).
MBS CLP=0 (cells) – Displays only if you selected a traffic
descriptor combination that includes MBS CLP=0. If so, specify
the MBS (in cells per second) for the combined high-priority
traffic (that is, the CLP=0 cell stream).
MBS CLP=0+1 (cells) – Displays only if you selected a TD
combination that includes MBS CLP=0+1. If so, specify the
MBS in CPS for the combined high- and low-priority traffic (that
is, the CLP=0+1 cell stream).
MCR CLP=0 (cells/sec) – Displays only if you selected a TD
combination that includes MCR CLP=0. If so, specify the MCR
in CPS for the combined high-priority traffic (that is, the CLP=0
cell stream).
Note: While the MCR TD is only applicable to a CBX 500 with
an FCP, this attribute is offered as a selection on non-CBX
endpoints. This is because even though one or both endpoints
may not be on a CBX with FCP, the PVC might traverse a CBX
500 FCP trunk. In this case, the provisioned attribute is used.
Configuring ATM PVCs
Configuring PMP Circuits
Action/Description
1/19/0510-79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbx 500Gx 550B-stdx 9000

Table of Contents