Table 3-6. Add Logical Port: CES Parameters Tab Fields (Continued)
Field
Rx Conditioning
This mode specifies the format of the conditioned data in the
Mode
receive direction (egress or local port). Specifies whether data,
signalling, both, or none are conditioned. If data is specified, the
data is conditioned using the value in the Rx Conditioning Data
field. If only signalling is specified, the signalling is conditioned
using the value in the Rx Conditioning Signal field. The
pull-down menu options are:
For more information on Trunk Conditioning, including range of
values and defaults, see
Conditioning."
Note: Not applicable for Unstructured Services.
Rx Force
This mode, which is used primarily for testing purposes,
Conditioning
specifies that the data and/or signalling is always conditioned in
Mode
the receive direction (egress or local port). This mode provides a
means for always overwriting the data and/or signalling
information. The pull-down menu options are:
For more information on Trunk Conditioning, including range of
values and defaults, see
Conditioning."
Note: Not applicable for Unstructured Services.
Rx Conditioning
The user supplied ABCD signalling bits (ABAB with SF1
Signal (0-1)
format) when the signal is conditioned in the receive direction
(egress or local port).
For more information on Trunk Conditioning including range of
values and defaults, see
Conditioning."
Note: Not applicable for Unstructured Services.
Carry CAS
Select the Yes or No button. For unstructured mode, this field
must be set to no.
For structured mode, when PPort CAS is set to Transport, Carry
CAS can be set to yes or no. When PPort CAS is set to Terminate,
Carry CAS is set to no.
Configuring CBX or GX Logical Ports
Action/Description
None
Data
Random Data
Buffer Data
Appendix I, "About Trunk
None (default when no testing is being done)
Data and Signalling
Signalling
Appendix I, "About Trunk
Appendix I, "About Trunk
Setting Logical Port Attributes
1/19/053-39