Starting Up the Printer
I-Mark Sensor
Printing > Advanced > Calibrate > I-Mark Sensor
Adjust the I-Mark sensor level manually.
The adjustment reference values are as follows:
Low
: 0.5 V or less
High-Low : 1.0 V or more
The I-Mark sensor has the following setting items:
1
Emission Level
2
Receiving Level
3
Slice Level
■ Manual Adjustment of I-Mark Sensor
1. Remove the label, and then set the liner. Align the liner so that the media sensor
does not detect the I-Mark (black mark).
2. Close the cover.
3. Select Calibrate > I-Mark Sensor > Emission Level.
4. Press the
adjusted to 0.5 or lower.
5. Press the
6. Select Calibrate > I-Mark Sensor > Receiving Level.
7. Press the
adjusted to meet the following:
Sensor High value - Sensor Low value
Sensor High value: I-Mark part
Sensor Low value: Liner part
Adjust the values so that the Sensor value in the Liner part is approximately 0.3 V
to 0.5 V. Then, pull the media to check that the I-Mark part value - the Label +
Liner parts value
8. Press the
Emission Level
Printing > Advanced > Calibrate > I-Mark Sensor > Emission Level
Adjust the I-Mark sensor emission level.
Emit
: Initial value
: Setting range : 0 to 3
60
Mobile printer PW208NX/PW208mNX
button to change the Emit value so that the Sensor value is
button to decide the value.
button to change the Recv value so that the Sensor value is
1.0 V
1.0 V.
button to decide the value.
: 1