Calibrate
Printing > Advanced > Calibrate
Adjust the media sensor level.
When there is malfunction of media detection, adjust the media sensor level (Gap and
I-mark sensor).
To adjust the media sensor, set the following items.
1
Auto-Calibration
2
Gap Sensor
3
I-Mark Sensor
Note
If the media does not feed correctly after executing Auto-Calibration,
contact your SATO reseller or technical support center.
Auto-Calibration
Printing > Advanced > Calibrate > Auto-Calibration
Perform auto-calibration for the selected media sensor.
Initial setting : Gap + I-Mark (PW208NX) / I-Mark (PW208mNX)
Setting options: Gap + I-Mark , Gap, I-Mark (PW208NX) / I-Mark (PW208mNX)
Gap + I-Mark: Adjust both Gap sensor and I-Mark sensor automatically.
Gap
: Adjust the Gap sensor level automatically.
I-Mark
: Adjust the I-Mark sensor level automatically.
Notes
• When using a PW208mNX, the Auto-Calibration is set to I-Mark. You
cannot change the setting.
• Before making an adjustment, set the specified media on the sensor and
close the cover. If you are using labels, remove the label from the liner.
Align it so that the media sensor does not detect the I-Mark (black mark).
Adjust the sensor level automatically.
Adjust the Gap sensor level manually.
Adjust the I-Mark sensor level manually.
Starting Up the Printer
For PW208NX:
For PW208mNX:
Mobile printer PW208NX/PW208mNX
57