AudioCodes Mediant 800B User Manual page 875

Enterprise session border controller analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
Conferencing Parameters
Web/EMS: Conference ID
[ConferenceID]
Web: Beep on Conference
[BipOnConference]
Web: Enable Conference DTMF Clamping
[EnableConferenceDTMFClamp]
Web: Enable Conference DTMF Reporting
[EnableConferenceDTMFReporting]
Web: Active Speakers Min. Interval
[ActiveSpeakersNotificationMinInterval]
Automatic Gain Control (AGC) Parameters
Web: Enable AGC
EMS: AGC Enable
[EnableAGC]
Version 6.6
‎ 5 1. Configuration Parameters Reference
Defines the Conference Identification string.
The valid value is a string of up to 16 characters. The
default is "conf".
Note: To join a conference, the INVITE URI must include
the Conference ID string preceded by the number of the
participants in the conference and terminated by a
unique number. For example:
INVITE sip:4conf1234@10.1.10.10
INVITE messages with the same URI join the same
conference.
Enables playing a beep when a participant joins or
leaves a conference (in the latter case, a beep of a
different pitch is heard).
[0] Disable
[1] Enable (default)
Determines the device logic once a DTMF is received on
any conference participant. If enabled, the DTMF is not
regenerated toward the other conference participants.
This logic is only relevant for simple conferencing
(NetAnn).
[0] Disable
[1] Enable (default)
Determines the device logic once a DTMF is received on
any conference participant. If enabled, the device reports
this DTMF in an out-of-band SIP message (according to
TxDTMFOptions). This logic is only relevant for simple
conferencing (NetAnn).
[0] Disable (default)
[1] Enable
Defines the minimum interval (in 100 msec units)
between each Active Speaker Notification (ASN) events
report. These events report on the active speakers in a
conference. The event is issued whenever the active
speakers change.
Minimum configurable interval between events is 500
msec (5 units). The range is 5 to 2147483647 units. The
default is 20 (i.e., 100 msec).
Enables the AGC mechanism. The AGC mechanism
adjusts the level of the received signal to maintain a
steady (configurable) volume level.
[0] Disable (default)
[1] Enable
Notes:
This parameter can also be configured in a Tel
Profile.
For a description of AGC, see Automatic Gain Control
875
Description
Mediant 800B GW & E-SBC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-sbc

Table of Contents