Parameter
Web: Device Behavior Upon
RADIUS Timeout
[BehaviorUponRadiusTimeout]
Web: Local RADIUS Password
Cache Mode
[RadiusLocalCacheMode]
Web: Local RADIUS Password
Cache Timeout
[RadiusLocalCacheTimeout]
Web: RADIUS VSA Vendor ID
[RadiusVSAVendorID]
Web: RADIUS VSA Access
Level Attribute
[RadiusVSAAccessAttribute]
[MaxRADIUSSessions]
EMS: RADIUS Auth Number of
Retries
[RADIUSRetransmission]
[RadiusTO]
User's Manual
attribute.
The valid range is 0 to 255. The default is 200 (i.e., Security
Administrator).
Defines the device's response upon a RADIUS timeout.
[0] Deny Access = Denies access.
[1] Verify Access Locally = (Default) Checks password locally.
Determines the device's mode of operation regarding the timer
(configured by the parameter RadiusLocalCacheTimeout) that
determines the validity of the user name and password (verified by
the RADIUS server).
[0] Absolute Expiry Timer = When you access a Web page, the
timeout doesn't reset, instead it continues decreasing.
[1] Reset Timer Upon Access = (Default) Upon each access to
a Web page, the timeout always resets (reverts to the initial
value configured by RadiusLocalCacheTimeout).
Defines the time (in seconds) the locally stored user name and
password (verified by the RADIUS server) are valid. When this
time expires, the user name and password become invalid and a
must be re-verified with the RADIUS server.
The valid range is 1 to 0xFFFFFF. The default is 300 (5 minutes).
[-1] = Never expires.
[0] = Each request requires RADIUS authentication.
Defines the vendor ID that the device accepts when parsing a
RADIUS response packet.
The valid range is 0 to 0xFFFFFFFF. The default is 5003.
Defines the code that indicates the access level attribute in the
Vendor Specific Attributes (VSA) section of the received RADIUS
packet.
The valid range is 0 to 255. The default is 35.
Defines the number of concurrent calls that can communicate with
the RADIUS server (optional).
The valid range is 0 to 240. The default is 240.
Defines the number of retransmission retries.
The valid range is 1 to 10. The default is 3.
Defines the time interval (measured in seconds) that the device
waits for a response before a RADIUS retransmission is issued.
The valid range is 1 to 30. The default is 10.