Parameter
Web/EMS: Use Destination As
Connected Number
[UseDestinationAsConnectedNu
mber]
Web: Caller ID Transport Type
EMS: Transport Type
[CallerIDTransportType]
Reject Anonymous Calls Per Port Table
[RejectAnonymousCallPerPort]
User's Manual
privacy.
Enables the device to include the Called Party Number, from
outgoing Tel calls (after number manipulation), in the SIP P-
Asserted-Identity header. The device includes the SIP P-
Asserted-Identity header in 180 Ringing and 200 OK responses
for IP-to-Tel calls.
[0] Disable (default)
[1] Enable
Notes:
For this feature, you must also enable the device to include
the P-Asserted-Identity header in 180/200 OK responses,
by setting the parameter AssertedIDMode to Add P-
Asserted-Identity.
If the received Q.931 Connect message contains a
Connected Party Number, this number is used in the P-
Asserted-Identity header in 200 OK response.
This parameter is applicable to ISDN, CAS, and/or FXO
interfaces.
Determines the device's behavior for Caller ID detection.
[0] Disable = The caller ID signal is not detected - DTMF
digits remain in the voice stream.
[1] Relay = (Currently not applicable.)
[3] Mute = (Default) The caller ID signal is detected from the
Tel/PSTN side and then erased from the voice stream.
Note: Caller ID detection is applicable only to FXO interfaces.
This table parameter determines whether the device rejects
incoming anonymous calls per FXS port. If enabled, when a
device's FXS interface receives an anonymous call, it rejects
the call and responds with a SIP 433 (Anonymity Disallowed)
response.
The format of this parameter is as follows:
[RejectAnonymousCallPerPort]
FORMAT RejectAnonymousCallPerPort_Index =
RejectAnonymousCallPerPort_Enable,
RejectAnonymousCallPerPort_Port,
RejectAnonymousCallPerPort_Module;
[\RejectAnonymousCallPerPort]
Where,
Enable = accept [0] (default) or reject [1] incoming
anonymous calls.
Port = Port number.
Module = Module number.
For example:
RejectAnonymousCallPerPort 0 = 0,1,1;
RejectAnonymousCallPerPort 1 = 1,2,1;
Note: This parameter is applicable only to FXS interfaces.